Hi
According to the information you have supplied, it looks like this is the
only database backup that you have. Is this correct?
There can be multiple reasons to why you cannot delete a database backup
volume from the volume history:
1. The database is the last database backup that you have(including
incrementals)
2. The database is the last database within the specific device class. TSM
will not allow you to delete the last database backup, despite the fact
that you might have other database backups bound to other device classes.
Best Regards
Daniel Sparrman
-----------------------------------
Daniel Sparrman
Exist i Stockholm AB
Propellervägen 6B
183 62 TÄBY
Växel: 08 - 754 98 00
Mobil: 070 - 399 27 51
Henrik Wahlstedt <shwl AT STATOIL DOT COM>
Sent by: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>
2004-04-29 14:59
Please respond to
"ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>
To
ADSM-L AT VM.MARIST DOT EDU
cc
Subject
Re: Get tape to status scratch.....
Hi,
Try a DELETE VOLHISTORY TODATE=TODAY-(X days) TYPE=DBBACKUP
//Henrik
Lars-Erik Öhman
<larsa.ohman@CA To: ADSM-L AT VM.MARIST DOT EDU
RNEGIE.SE> cc: (bcc: Henrik Wahlstedt)
Sent by: "ADSM: Subject: Get tape to status
scratch.....
Dist Stor
Manager"
<ADSM-L AT VM DOT MARI
ST.EDU>
2004-04-29
14:34
Please respond
to "ADSM: Dist
Stor Manager"
Evironment:
Server OS: Windows 2000
TSM ver: 5.1.7.0
I have an old tape that was used for a database backup once, that I want
to
make a scratch tape of, but it wont work. Can anyone help me with this?
There is no problem if I do it on another tape.
q libvol
LB6 194ABCL1 Private Data 4,130
LB6 195ABCL1 Private Data 4,113
LB6 196ABCL1 Private Data 4,148
LB6 197ABCL1 Private DbBackup 4,167
LB6 198ABCL1 Private Data 4,153
LB6 199ABCL1 Private Data 4,165
LB6 470AALL1 Private Data 4,163
update libvol lb6 197ABCL1 status=scratch
ANR8443E UPDATE LIBVOLUME: Volume 197ABCL1 in library LB6 cannot be
assigned a status of SCRATCH.
/Larsa
-------------------------------------------------------------------