ADSM-L

Number of usable cells in a 3494

2003-12-08 11:45:15
Subject: Number of usable cells in a 3494
From: "Thomas Rupp, Vorarlberger Illwerke AG" <Thomas.Rupp AT ILLWERKE DOT AT>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Mon, 8 Dec 2003 17:43:50 +0100
Hi TSM-ers,

I'm running TSM 4.2.2.8 on a NSM with a 3494 library with 210 cells 
(counted by myself).
mtlib -l /dev/lmcp0 -qL only reports 206 cells
   number of cells............206
   available cells............0

In the library I find one CE and two cleaning cartridges.

mtlib -l /dev/lmcp0 -vqK -s fff6 shows 
   number of volumes....1

mtlib -l /dev/lmcp0 -vqK -s fffd shows
   number of volumes....2 

One of this 4 "missing" cells is the special cell in the upper left corner but
how about the remaining 3 cells?
How can I use this cells? Could the CE and cleaning cartridges be counted
twice by the 3494?

I never had much to do with the 3494 so the solution to this "problem" might
be quite obvious.

Thanks and kind regards
Thomas Rupp

<Prev in Thread] Current Thread [Next in Thread>