Paul,
We found the same thing when we upgraded to 3.1.2.1. I have a PMR open
(29691,500), however, the only workaround
at this time is to manually close the E/E port by pressing the open/close
button. If you don't manually close it, any subsequent attempts to use the E/E
port will fail with an I/O error, with the description: "device not in a state
capable of
performing request".
Hope this helps,
Dennis Haas
IBM Global Services - St. Louis Mo.
E-mail: dhaas AT us.ibm DOT com
>>Paul Deveau wrote:
>
Hi:
>
>I upgraded to ADSM v3.1.2.1 over the weekend and discovered a problem.
>
>When I checkout a volume into my Exabyte 120, take out the cartridge, and
>do a reply, the robot stays put. Before I upgraded the door would close
>automatically after the reply, but now is stays open and I have to
>manually close it.
>
>Paul Deveau
>Centrale des ordinateurs - Computer Centre
>562-5800 x3774
|