we upgraded from netbackup 7.0.1 which has worked for over a year, to 7.1.0.3
and the ndmp tape drives go down and stay down, and tpautoconf gives the
following output:
master:.../bin# tpautoconf -verify netappfas3160a
Connecting to host "netappfas3160a" as user "root"...
Failed to connect to port 10000
: host "netappfas3160a" failed
NDMP failed to verify host
master:.../bin# tpautoconf -probe netappfas3160a
: host "netappfas3160a" failed
Internal NDMP error
master:.../bin# cat /usr/openv/netbackup/version
HARDWARE LINUX_RH_X86
VERSION NetBackup 7.1.0.3
RELEASEDATE Wed Dec 07 20:38:17 CST 2011
BUILDNUMBER 20111207
old version:
HARDWARE LINUX_RH_X86
VERSION NetBackup 7.0.1
RELEASEDATE Thu Jul 08 02:04:00 CDT 2010
BUILDNUMBER 20100707
i had copied openv/* to openv_7.0.1/* so reverting back to 7.0.1 was easy, just
shutdown netbackup and rename the 2 dirs. i upgraded another site with the
same netbackup environment (os and library, 2 netapps, etc) with no problems.
has anyone else experienced this problem? telnet to the netapp port works
fine. when the original openv dir is back in place, tpconfig shows the drive
up and backups work fine. is 7.1.0.3 trying to use a different os network
shared library object that may be missing?
thanks,
jerald
more info:
master:.../bin# tpconfig -l
Device Robot Drive Robot Drive Device
Second
Type Num Index Type DrNum Status Comment Name Path
Device Path
robot 0 - TLD - - - - /dev/sg4
drive - 1 hcart 1 DOWN netappfas3160b lto5_drv1 /dev/nrst0a
drive - 2 hcart 2 DOWN netappfas3160a lto5_drv2 /dev/nrst0a
drive - 3 hcart 3 UP - lto5_drv3 /dev/nst1
drive - 4 hcart 4 UP - lto5_drv4 /dev/nst0
master:.../# ssh netappfas3160a sysconfig -t
Tape drive (0b.73) IBM ULTRIUM-TD5
rst0l - rewind device, format is: LTO-3(ro)/4 4/800GB
nrst0l - no rewind device, format is: LTO-3(ro)/4 4/800GB
urst0l - unload/reload device, format is: LTO-3(ro)/4 4/800GB
rst0m - rewind device, format is: LTO-3(ro)/4 8/1600GB cmp
nrst0m - no rewind device, format is: LTO-3(ro)/4 8/1600GB cmp
urst0m - unload/reload device, format is: LTO-3(ro)/4 8/1600GB cmp
rst0h - rewind device, format is: LTO-5 1600GB
nrst0h - no rewind device, format is: LTO-5 1600GB
urst0h - unload/reload device, format is: LTO-5 1600GB
rst0a - rewind device, format is: LTO-5 3200GB cmp
nrst0a - no rewind device, format is: LTO-5 3200GB cmp
urst0a - unload/reload device, format is: LTO-5 3200GB cmp
master:.../# ssh netappfas3160a ndmpd status
ndmpd ON.
No ndmpd sessions active.
master:.../# cat /etc/red*rel*
Red Hat Enterprise Linux Server release 5.5 (Tikanga)
****************************************************************
Confidentiality Note: The information contained in this
message, and any attachments, may contain confidential
and/or privileged material. It is intended solely for the
person(s) or entity to which it is addressed. Any review,
retransmission, dissemination, or taking of any action in
reliance upon this information by persons or entities other
than the intended recipient(s) is prohibited. If you received
this in error, please contact the sender and delete the
material from any computer.
****************************************************************
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|