Veritas-bu

Re: [Veritas-bu] Netbackup SG devices and Solaris 9

2008-05-28 10:41:06
Subject: Re: [Veritas-bu] Netbackup SG devices and Solaris 9
From: "Hudson, Steve" <Steve.Hudson AT ironmountain DOT com>
To: "Marianne Van Den Berg" <mvdberg AT stortech.co DOT za>
Date: Wed, 28 May 2008 10:20:41 -0400

Yes but we found the problem. We are using the Leadville driver and with this Driver The WWN of the tape drives have to be in the sg.conf and sg.links files. It was not and after I added them and ran sg.install I can see the 4 tape drives now….Thanks for everyones input on this…..

 


From: Marianne Van Den Berg [mailto:mvdberg AT stortech.co DOT za]
Sent: Wednesday, May 28, 2008 9:22 AM
To: Hudson, Steve
Subject: RE: [Veritas-bu] Netbackup SG devices and Solaris 9

 

Have you done a sg.build and sg.install (as per the Device Config guide - txt version in /usr/openv/volmgr)?

Marianne



-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu on behalf of Hudson, Steve
Sent: Wed 5/28/2008 3:06 PM
To: Dominik Pietrzykowski
Cc: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Netbackup SG devices and Solaris 9

Cfgadm shows the 4 LTO3 drives. The dev/rmt entries are 0cbn thru 3cbn.
But when I run scan or tpautoconf I get nothing nada zilch........



________________________________

From: Dominik Pietrzykowski [mailto:dominik_pietrzykowski AT toll.com DOT au]
Sent: Tuesday, May 27, 2008 10:48 PM
To: Hudson, Steve
Cc: veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] Netbackup SG devices and Solaris 9





What does cfgadm show ?



What /dev/rmt paths is it coming back with ????



Are you seeing any drives at all or nothing ???



________________________________

From: Hudson, Steve [mailto:Steve.Hudson AT ironmountain DOT com]
Sent: Wednesday, 28 May 2008 6:07 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Netbackup SG devices and Solaris 9



Having a heck of a time getting my new Solaris 9 Media server to see
tape. The setup is an L700 with 4 LTO 3 drives with a Decru Appliance in
the path. Just spent 2 hours on the phone with Symantec support and got
nowhere. Any one have any suggestions or tips .....????? 

________________________________

The information contained in this email message and its attachments is
intended only for the private and confidential use of the recipient(s)
named above, unless the sender expressly agrees otherwise. Transmission
of email over the Internet is not a secure communications medium. If you
are requesting or have requested the transmittal of personal data, as
defined in applicable privacy laws by means of email or in an attachment
to email you must select a more secure alternate means of transmittal
that supports your obligations to protect such personal data. If the
reader of this message is not the intended recipient and/or you have
received this email in error, you must take no action based on the
information in this email and you are hereby notified that any
dissemination, misuse, copying, or disclosure of this communication is
strictly prohibited. If you have received this communication in error,
please notify us immediately by email and delete the original message.

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu