> But what if you are using the same series of barcodes for different
> media? Is this a no-no and there is no work around?
> I have the same issue where I inventory a robot with LTO drive/media
> and it defaults to DLT3 and creates a new volume group. I have to use
> the GUI Configure Volumes to correct them as HCART2 and then manually
> move them from the Netbackup pool they had been put in to the scratch
> pool.
Unless you can tell which is which by looking at the barcode, I don't
know any way to get the system to do this automatically. The barcode
rules appear to be shared by all robots on a particular media server.
If you could separate the robots to different media servers, then you
could put different rules on each.
--