I've heard this complaint before, and I wish they would fix it. He is
referring to what happens when you actually lose power. Is it dangerous to
the library when this happens?
At 04:28 PM 11/30/00 -0800, Joshua Fielden wrote:
> > When power is dropped, the arm free falls to the bottom with the only
> drag being
> > that of the pulleys. It would've been nice if the arm had been better
> counter
> > weighted or had some kind of brake to support it's weight in the power off
> > situation, at least nicer than hearing that unsettling whine followed by a
> > thunk.
>
>Are you using the 'shutdown' procedure from the panel, or just pulling
>power after the JB is quieted?
---
W. Curtis Preston, Principal Consultant at Collective Technologies
Email: curtis AT colltech DOT com (Best way to contact me)
Work : 408 452 5555 (Leave a message.)
Pager: 800 946 4646, pin#1436065 (If urgent.)
Tap into the Collective Intellect (TM): http://www.colltech.com
Backup & Restore resources: http://www.backupcentral.com
|