On 20/04/11, Steffen Fritz (fritzsf AT googlemail DOT com) wrote:
> my Dell Powervault 124T autochanger is loaded with LTO-4 tapes. When I
> run the job, it terminates with an error after 1. 000 G (999.2 MB).
> The job should save 50 GB (one file from another weekly job) per
> month. Error message is "ERR=broken pipe" and something with MTWEOF.

I had this problem with our 124T when the drive was faulty. It took
quite a while to find the problem, but doing long reads and writes using
dd eventually proved the problem, and Dell swapped the unit out.

Our drive is a Quantum. Apparently the 124Ts with IBM drives are more
reliable. If you have an IBM drive you can use the IBM itdt utility to
test it, otherwise btape or dd are the best bet.

Naturally, you may also have tape errors.

Good luck.

-- 
Rory Campbell-Lange
rory AT campbell-lange DOT net
 
Campbell-Lange Workshop
www.campbell-lange.net
0207 6311 555
3 Tottenham Street London W1T 2AF
Registered in England No. 04551928

------------------------------------------------------------------------------
Benefiting from Server Virtualization: Beyond Initial Workload 
Consolidation -- Increasing the use of server virtualization is a top
priority.Virtualization can reduce costs, simplify management, and improve 
application availability and disaster protection. Learn more about boosting 
the value of server virtualization. http://p.sf.net/sfu/vmware-sfdev2dev
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users

<Prev in Thread] Current Thread [Next in Thread>