Hello,

18.12.2009 13:18, Sergio Belkin wrote:
> Hi,
> 
> Today I run into a "mismatch error", but is the difference of Volume
> and Catalog is of more than one file :(
> 
> This is the message
> 
> 18-Dec 08:46 supernoc-sd JobId 468: Error: Bacula cannot write on tape
> Volume "JUESEP09LTO" because:
> The number of files mismatch! Volume=385 Catalog=316
> 18-Dec 08:46 supernoc-sd JobId 468: Marking Volume "JUESEP09LTO" in
> Error in Catalog.
> 
> It's weird because there was not problem of this kind...

Probably an aborted job (due to bacula restart?) some time earlier.

> Only I did was modify volume retention parameters on file
> configuration and run update pool on bconsole, could that the source
> of this problem?

I don't think so.

I would suggest to just set this volume to status "Used" and let the 
normal recycling routine do its work.

Cheers,

Arno

> Thanks in advance!

-- 
Arno Lehmann
IT-Service Lehmann
Sandstr. 6, 49080 Osnabrück
www.its-lehmann.de

------------------------------------------------------------------------------
This SF.Net email is sponsored by the Verizon Developer Community
Take advantage of Verizon's best-in-class app development support
A streamlined, 14 day to market process makes app distribution fast and easy
Join now and get one step closer to millions of Verizon customers
http://p.sf.net/sfu/verizon-dev2dev 
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users

<Prev in Thread] Current Thread [Next in Thread>