How to tell the next tape.
2006-12-06 12:43:58
The following is an error message from my last amanda 2.5.1p1 run.
These dumps were to tape D00021.
*** A TAPE ERROR OCCURRED: [No more writable valid tape found].
Some dumps may have been left in the holding disk.
Run amflush to flush them to tape.
The next 3 tapes Amanda expects to use are: D00022, D00023, D00024.
My amanda.conf shows the following:
dumpcycle 6
runspercycle 0
tapecycle 30
runtapes 1
What program can I run that will tell me which tape will be used in the next
amanda run. I know about amadmin tape but there sometimes seems to be a
difference as to what amadmin and amdump use for the next tape.
Thanks
_____________________________________________________________________
Robert P. McGraw, Jr.
Manager, Computer System EMAIL: rmcgraw AT purdue DOT edu
Purdue University ROOM: MATH-807
Department of Mathematics PHONE: (765) 494-6055
150 N. University Street FAX: (419) 821-0540
West Lafayette, IN 47907-2067
smime.p7s
Description: S/MIME cryptographic signature
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
- How to tell the next tape.,
McGraw, Robert P. <=
|
|
|