Re: 2 devices on one machine
2003-10-13 11:30:30
--On Monday, October 13, 2003 16:18:28 +0100 Tom Brown <tom.brown AT
goodtechnology DOT com> wrote:
>> to follow up to myself here i have managed to get the single drive working
>> fine - The issue now seems to be with the changer.
>>
>> Using mtx i can load and unload tapes but when i run amcheck i get the
>> following error
>>
>> amcheck-server: could not get changer info: could not determine current
>> slot, are you sure your drive slot is 1
>>
>> I have changed all references to nst0 to point to nst1 in my config for
> this
>> setup but still this error - i have searched the archives for this one but
>> can't seem to find a solution.
>
> i'm still having an issue and here is an output from the latest debug from
> chg-zd-mtx
>
> $ more /tmp/amanda/chg-zd-mtx.20031013170311.debug
> chg-zd-mtx: debug 1 pid 2919 ruid 11 euid 11: start at Mon Oct 13 17:03:11
> 2003
> 17:03:11 Arg info:
> $# = 1
> $0 = "../../libexec/chg-zd-mtx"
> $1 = "-info"
> 17:03:11 Running: /opt/mtx/sbin/mtx status
> 17:03:11 Exit code: 0
> Stdout:
> Storage Changer /dev/sg2:1 Drives, 6 Slots ( 0 Import/Export )
> Data Transfer Element 0:Empty
> Storage Element 1:Full
> Storage Element 2:Full
> Storage Element 3:Full
> Storage Element 4:Full
> Storage Element 5:Full
> Storage Element 6:Full
> 17:03:11 Config info:
> firstslot = "1"
> lastslot = "5"
> cleanslot = "-1"
> cleancycle = "120"
> offline_before_unload = "1"
> unloadpause = "0"
> autoclean = "0"
> autocleancount = "99"
> havereader = "0"
> driveslot = "1"
> poll_drive_ready = "3"
> max_drive_wait = "120"
> 17:03:11 Exit (2) -> <none> could not determine current slot, are you sure
> your drive slot is 1
> chg-zd-mtx: pid 3060 finish time Mon Oct 13 17:03:11 2003
>
> really not having much luck with this idea of having 2 drives on one
> machine.
>
> thanks
>
Make sure that each amanda.conf specifies a different changerfile.
Each changerfile needs chgtapedev set to a different tape drive
(just use the single digit [0,1,2...]).
If both tape drives are in the same changer, you need to specify a different
range of slots for each amanda config.
Frank
--
Frank Smith fsmith AT hoovers DOT com
Systems Administrator Voice: 512-374-4673
Hoover's Online Fax: 512-374-4501
|
|
|