Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Networker\]\s+Saveset\s+Recovery\s+using\s+RMAN\s*$/: 44043 ]

Total 44043 documents matching your query.

201. Re: [Networker] NW 8 seems to eject tapes when group finishes (score: 1)
Author: Preston de Guise <enterprise.backup AT GMAIL DOT COM>
Date: Fri, 12 Jul 2013 06:39:50 +1000
On 11/07/2013, at 23:51 , Michael Leone <Michael.Leone AT PHA.PHILA DOT GOV> wrote: NetWorker 8 documentation states that the idle device timer was set to 10 minutes by default with that version. Che
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00041.html (13,256 bytes)

202. [Networker] NW 8 seems to eject tapes when group finishes (score: 1)
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Thu, 11 Jul 2013 13:48:52 -0700
Preston, if you click the '?' in the GUI for online help, you can see the units (minutes or seconds). +-- +--
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00042.html (12,432 bytes)

203. Re: [Networker] NW 8 seems to eject tapes when group finishes (score: 1)
Author: "Werth, Dave" <dave.werth AT GARMIN DOT COM>
Date: Thu, 11 Jul 2013 22:57:35 +0000
When I upgraded from 7.6.2 to 8.x I had the same thing happen. The value is in minutes and just set it to zero to prevent the tapes from being ejected. Dave Werth Garmin AT, Inc. Salem, Oregon --Orig
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00043.html (13,915 bytes)

204. [Networker] NW 8 seems to eject tapes when group finishes (score: 1)
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Thu, 11 Jul 2013 21:25:57 -0700
I do not remember that this was an issue when we updateded to NW 8. So i assume that the 10 minutes were already in place. However, 0 may have been set by a much older version. And if you just update
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00044.html (12,903 bytes)

205. [Networker] Helen Jenkinson is out of the office. (score: 1)
Author: Helen Jenkinson <h.jenkinson AT MANCHESTER.GOV DOT UK>
Date: Fri, 12 Jul 2013 18:21:50 +0100
I will be out of the office starting 12/07/2013 and will not return until 30/07/2013. All requests / enquiries should be routed through the Service Desk 0161 234 1234. ** This email and any files tra
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00045.html (11,234 bytes)

206. Re: [Networker] AFTD device/nsrstage command with 8.0.1.5 (score: 1)
Author: Dag Nygren <dag AT NEWTECH DOT FI>
Date: Mon, 15 Jul 2013 12:14:20 +0300
Hi! Yes, this was true in earlier versions. From 8.x up the selection mechanism is different. Networker will now do the recover from any instance that is currently available. So if you have the clone
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00046.html (12,290 bytes)

207. Re: [Networker] AFTD device read (score: 1)
Author: dave2 AT CAMBRIDGECOMPUTER DOT COM
Date: Tue, 16 Jul 2013 10:36:20 -0400
I tested tape selection with 7.6, and found that if the primary copy was offline, and the clone was online, it would use the clone copy without having to mark the original suspect, or anything weird.
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00047.html (12,931 bytes)

208. Re: [Networker] AFTD device read (score: 1)
Author: Dag Nygren <dag AT NEWTECH DOT FI>
Date: Tue, 16 Jul 2013 22:51:45 +0300
Could well have been already in 7.6. Fairly recent anyway. Best Dag
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00048.html (10,775 bytes)

209. [Networker] Using nsradmin to export the configuration (score: 1)
Author: "Clark, Patricia A." <clarkpa AT ORNL DOT GOV>
Date: Wed, 17 Jul 2013 16:35:02 -0400
I have just been getting back into the driver's seat and was working with nsradmin to export the networker configuration. Even with turning on the options to show everything, the only types that are
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00049.html (11,644 bytes)

210. Re: [Networker] Using nsradmin to export the configuration (score: 1)
Author: "Werth, Dave" <dave.werth AT GARMIN DOT COM>
Date: Wed, 17 Jul 2013 21:02:52 +0000
That looks to me like what you would see running nsradmin on a client system, not the NetWorker server. Dave Werth Garmin AT, Inc. Salem, Oregon --Original Message-- From: EMC NetWorker discussion [m
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00050.html (12,787 bytes)

211. Re: [Networker] Using nsradmin to export the configuration (score: 1)
Author: Tim Mooney <Tim.Mooney AT NDSU DOT EDU>
Date: Wed, 17 Jul 2013 16:04:35 -0500
In regard to: [Networker] Using nsradmin to export the configuration,...: I have just been getting back into the driver's seat and was working with nsradmin to export the networker configuration. Eve
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00051.html (12,304 bytes)

212. [Networker] Using nsradmin to export the configuration (score: 1)
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Wed, 17 Jul 2013 14:41:49 -0700
I just wonder what you want to achieve with the "(total) export of the NW configuration". - For the look at a specific resource, such is an overkill. - For a backup, you have all resources in the dai
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00052.html (11,867 bytes)

213. [Networker] The Best Way (score: 1)
Author: Vishal Gupta <vvishalgupta AT GMAIL DOT COM>
Date: Thu, 18 Jul 2013 12:11:09 +0530
Hi Guys, Need your valuable suggestions/advice/tips to achieve the following: DC site: 1 NW server - version 8.x on WIN 2008 4 Storage nodes 1 DD 890 1 LTO5 library 400-500 clients (source capacity =
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00053.html (10,686 bytes)

214. [Networker] The Best Way (score: 1)
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Thu, 18 Jul 2013 00:01:17 -0700
Hi Vishal, that's almost our scenario, Just that we work with 2 SNs. We just do B2D with monthly clones to tape. However there is a big difference: 2 use 2DDs so that if the path to a DD or the machi
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00054.html (10,892 bytes)

215. Re: [Networker] Using nsradmin to export the configuration (score: 1)
Author: "Clark, Patricia A." <clarkpa AT ORNL DOT GOV>
Date: Thu, 18 Jul 2013 08:09:38 -0400
Thank you Tim, Dave, and bingo. I was using "-p nsrexecd" - once I dropped the "d" everything was present. It has been a couple of years and this was only an end to a means to find the rest of the da
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00055.html (13,034 bytes)

216. [Networker] Using nsradmin to export the configuration (score: 1)
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Thu, 18 Jul 2013 06:53:02 -0700
BTW ... thinking about your issue i was reminded that i have written a command for a NW/Windows server that does exactly what you want - it is just exporting the resource files by merging all files i
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00056.html (12,186 bytes)

217. [Networker] Networker 8.0.1.6 NDMP backups failing (score: 1)
Author: "Roberts, Justin (GE, Appl & Light)" <Justin.Roberts2 AT GE DOT COM>
Date: Thu, 18 Jul 2013 18:21:14 +0000
After updating to 8.0.1.6 I'm getting the below error message when backing up BlueArc NAS Devices. Anyone ever seen this? "Error removing temporary FH index directory: Directory not empty" Justin M R
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00057.html (11,423 bytes)

218. [Networker] NMM 2.4 sp1 and Exchange 2013 sp3 (score: 1)
Author: "Browning, David" <DBrown AT LSUHSC DOT EDU>
Date: Thu, 18 Jul 2013 18:38:14 +0000
Our Exchange administrators are in the process of upgrading our Exchange 2013 servers to SP3, and we have some questions. Right now, our backup server is running 7.6.2.7, with a planned upgrade to 8.
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00058.html (11,897 bytes)

219. Re: [Networker] NMM 2.4 sp1 and Exchange 2013 sp3 (score: 1)
Author: "Browning, David" <DBrown AT LSUHSC DOT EDU>
Date: Thu, 18 Jul 2013 18:42:44 +0000
I apologize, it is Exchange 2010 SP3, not Exchange 2013. David M. Browning Jr. IT Project Coordinator Enterprise Backups and Help Desk http://www.lsuhsc.edu/ithelpdesk Twitter: @LSUHSCNO_IT Our Excha
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00059.html (12,510 bytes)

220. Re: [Networker] NMM 2.4 sp1 and Exchange 2013 sp3 (score: 1)
Author: "Goslin, Paul" <PGoslin AT CINCOM DOT COM>
Date: Thu, 18 Jul 2013 19:10:12 +0000
Hi David, It works. We are running such a setup - our server is 7.6.4 backing up an Exchange 2010 server using nmm24.build375 ... We Have tested restores also and they work... Mailbox / folder restor
/usr/local/webapp/mharc-adsm.org/html/Networker/2013-07/msg00060.html (13,359 bytes)


This search system is powered by Namazu