Re: [nv-l] Nortel Concentrator CPU
2005-07-18 03:51:42
At 11:46 AM 08-07-05 -0400, reamd AT Nationwide DOT com wrote:
Hi All,
Can someone tell me what mib they use for monitoring the CPU on
the Nortel Concentrator. Through a mib browser I found
.1.3.6.1.2.1.25.5.1.1.1 but the description is a little confusing.
Thanks, Dave
Dave,
You probably need to look in the Nortel specifications or manuals for this
device.
The OID that you quote is from the IETF standard Host Resources MIB. This
MIB is meant for host computers (e.g. servers) rather than network devices.
The OID is that of a MIB variable that shows the CPU time used by a running
process on such a host computer.
My guess is that it is unlikely that a network equipment vendor would
choose to implement this MIB, so you'll probably have to find a Nortel
enterprise MIB.
Joe Fernandez
Kardinia Software
jfernand AT kardinia DOT com