Hi all,
I´m on the way to send events to our TEC from a windows2000 based Netview
(7.1.1).
1)
When sending events manually via command line using the "event" binary, it
is working. I can see the events in the TEC reception log and on the event
console.
2)
When stopping the "netmon" a FATAL event is sent to the TEC console and the
TEC reception log too (message is "netmon probably disconnected from
trapd"). So far everything seems to be OK.
3)
Now the story starts.
In case netview can´t reach an interface, it tries to send an event to the
TEC console, but for some reason it doesn´t succeed, all the time I get the
following error message written to the "nvtecad" logfile.
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, r_ov_snmpprint.c line
0078: octet string nil pointer
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 0 nvApplNbr: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 1 nvObject: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 2 nvEventDescr: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 3 nvEventInfo: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 4 nvEventOptInfo: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 5 1.3.6.1.4.1.2.6.3.1.1.11.0: NULL
Mon Jan 13 17:19:58 2003 MAJOR: TECIO , err 01, .\tec_io.c line
0285: Event could not be sent properly
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, r_ov_snmpprint.c line
0078: octet string nil pointer
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 0 nvApplNbr: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 1 nvObject: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 2 nvEventDescr: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 3 nvEventInfo: 0
Mon Jan 13 17:19:58 2003 VERBOSE: DRVSPEC, err 00, driver_ov.c line
1104: Var 4 nvEventOptInfo: 0
Mon Jan 13 17:19:58 2003 MAJOR: TECIO , err 01, .\tec_io.c line
0285: Event could not be sent properly
I looked in the forum´s mail archieve and found a hint to use the "non tme
tec adapter", so I did. I stopped the tecad_nv.exe process running in the
task maanger. I stopped it and restarted it via command line the following
way: tecad_nv6k_non_tme -c \usr\ov\conf\tecad_nv6k.conf
Unfortunately I have to say, that nothing changed, i.e no events get
received by the TEC as still no events can be sent out. Why?
Someone in the list has a clue about it??? Many thanks in advance!!!
best regards,
> Thorsten Mildeberger
>
> EMS Solutions - SMC Tools & Automation
> GOSD - Central Region
> EDS Deutschland GmbH
> Eisenstr. 43
> 65428 Rüsselsheim
> Tel.: +49 (0) 6142 80-3706
> Fax.: +49 (0) 6142 80-3030
> mailto:thorsten.mildeberger AT eds DOT com
>
|