Thank you Stephen and James,

Note that i am already forwarding Nodedown/up events from NetView to TEC.
I have a NetView ruleset filtering and correlating these events based upon
some smartsets containing the systems i want to monitor.
This is because the TEC can then create TSD trouble tickets for these
nodes.
But these are all NetView generated events (N)
The thing is, i now need to capture Compaq Insight Manager traps coming
from a few hundred NetWare servers.
The CIM module for Tivoli Enterprise comes with lots of ready to use
rulesets for the TEC aswell as the .cds, .oid and .baroc files needed...
I can't use any of this when the events need to pass through trapd i
believe.
and i'm not (yet) an expert in writing NetView rulesets.

I do have only "1" system for Tivoli!
I considered installing another one solely for the purpose of this TEC SNMP
Adapter but it would probably not be a SUN3500 ;-)
I know this situation is a bit unusual but i am checking out all the
options.

Thanks






Stephen_Hochstetler AT tivoli DOT com on 12/07/2001 19:05:29

Please respond to tme10 AT list.ephibian DOT com
                                                              
                                                              
                                                              
 To:      tme10 AT list.ephibian DOT com                             
                                                              
 cc:      (bcc: Pieter Van Cauwenberghe/CSI/BE)               
                                                              
                                                              
                                                              
 Subject: Re: tme10 [NV-L][TEC] SNMP port 162                 
                                                              









Peter,

My background is as a NetView consultant.    I would give a strong
recommendation for NetView to receive the SNMP traps....and use NetView's
built in TEC adapter to send just the interesting SNMP traps to TEC for
additional correlation.   Do not use the TEC SNMP adapter.    This will
give you immense control/filtering capabilities to send TEC only what it
needs and speed up your correlation.

Reasons -
    NetView has a larger capacity for handling traps than TEC does.
    NetView generates its own traps - example: Interface down, which can be
sent to TEC via the NetView TEC adapter
    You can build a NetView ruleset that does some correlation/filtering of
traps before they go to NetView.
          -- example:   Interface Up came in at next polling cycle, which
cleared Interface Down....so don't send either to TEC
         --- example:   I am not interested for SNMP traps from desktops in
offices

To send events to TEC from NetView, you will need a NetView ruleset....you
can choose Forward_All if you want to...to test it out (ruleset out of the
box)
You just need to bring up 'Configure', then choose 'Configure Event
forwarding to TEC'.    It will ask for hostname for TEC and NetView
ruleset. Go through the other steps in the documentation to get the proper
baroc file in TEC that ships with NetView before turning on the event
forwarding.

Thanks,
Stephen Hochstetler/Tivoli Systems       shochste AT tivoli DOT com
International Technical Support Organization (ITSO) - Austin
Office - 512-436-8564   Mobile - 919-247-3468


Pieter_Van_Cauwenberghe AT csi DOT [email protected] on 07/12/2001 12:19:31 
PM

Please respond to tme10 AT list.ephibian DOT com

Sent by:  owner-tme10 AT list.isis2000 DOT com


To:   nv-l AT tkg DOT com, tme10 AT list.ephibian DOT com
cc:
Subject:  tme10 [NV-L][TEC] SNMP port 162






Hi all,

Some advice please,

Envir: NetView 6.0.1 and TEC 3.7 on solaris 2.6, SUN3500

I would like to monitor network devices with NetView but correlate SNMP
traps sent by these and other devices with the TEC through its SNMP
Adapter.
But... NetView and TEC (and the SNMP Adapter) are running on the same
system!
So, If this TEC SNMP Adapter is listening on port 162, NetView's trapd
cannot receive SNMP traps from SNMP Agents.
(and vice versa)
All other NetView features i want to use seem to perform ok.

As long as the TEC SNMP Adapter is started before NetView's trapd daemon,
this design seems to work fine.

Has anyone else done this?
Are there any drawbacks?
(both from the NetView and the TEC point of view)
Should or shouldn't i be doing this?

ThanQ, Pieter



Copyright (c) 2000 Pieter_Van_Cauwenberghe AT csi DOT be.  All rights reserved.

TME10 list information (policies, posting, digest version, archives,
downloads,
unsubscribing):  http://www.techgroups.tivoli.ephibian.com/listserve
TME10 list searchable archive:  http://tme10.uio.no/
TME10 list searchable archive:  http://www.vk.net/tivoli/Tivoli-List.nsf
TME10 List FAQ:  http://www.concentric.net/~codie/tme10listfaq.html
Tivoli Search Site:  http://www.tivoli.com/support/knowledgebase/index.html





Copyright (c) 2000 Stephen_Hochstetler AT tivoli DOT com.  All rights reserved.

TME10 list information (policies, posting, digest version, archives,
downloads,
unsubscribing):  http://www.techgroups.tivoli.ephibian.com/listserve
TME10 list searchable archive:  http://tme10.uio.no/
TME10 list searchable archive:  http://www.vk.net/tivoli/Tivoli-List.nsf
TME10 List FAQ:  http://www.concentric.net/~codie/tme10listfaq.html
Tivoli Search Site:  http://www.tivoli.com/support/knowledgebase/index.html


<Prev in Thread] Current Thread [Next in Thread>