nv-l

Re: NV6k to TEC - resolved

1999-12-23 04:25:30
Subject: Re: NV6k to TEC - resolved
From: "Smeriglio,Luca,VEVEY,FC-SIL/INF." <Luca.Smeriglio AT NESTLE DOT COM>
To: nv-l AT lists.tivoli DOT com
Date: Thu, 23 Dec 1999 10:25:30 +0100
Tanks for the tip James !
I found it. The class is OV_Node_Down and it's actually defined in
tecad_ov.baroc,
as well as every Netview internal trap, which is really cool.

Thanks again and merry XMas,
Luca

> -----Original Message-----
> From: James Shanks [SMTP:James_Shanks AT TIVOLI DOT COM]
> Sent: Wednesday, December 22, 1999 5:19 PM
> Subject:      Re: NV6k to TEC
>
> I don't know the TEC default but it is easy enough for you to find out.
> Go to your TEC box and browse the tecad_nv6k.cds file and see for
> yourself.  Do
> a search on the specific id of the trap you are looking for and if it is
> there,
> then you will see what class is being used.  If you don't find it, then it
> is
> the default.
>
> James Shanks
> Tivoli (NetView for UNIX) L3 Support
>
>
>
> "Smeriglio,Luca,VEVEY,FC-SIL/INF." <Luca.Smeriglio AT NESTLE DOT COM> on 
> 12/22/99
> 10:52:59 AM
>
> Please respond to Discussion of IBM NetView and POLYCENTER Manager on
> NetView
>       <NV-L AT UCSBVM.UCSB DOT EDU>
>
> To:   NV-L AT UCSBVM.UCSB DOT EDU
> cc:    (bcc: James Shanks/Tivoli Systems)
> Subject:  NV6k to TEC
>
>
>
>
> Hi list,
>
> I have a small question.
>
> As I'm already using custom scripts for Node Down/Up events within
> Netview,
> I thought it may be simpler to use wpostemsg inside those scripts to
> notify
> the TEC.
> (thus allowing me to maybe add custom slots for additional information)
>
> The question is, is there a specific Class for NV6K_Node_Down and
> NV6K_Node_Up
> defined in the tecad_nv6k.baroc file, or is the "IBM_Default_Trap" Class
> used for those
> events normally ?
>
> Thanks for your help and merry X-Mas everyone !
>
> Cheers,
> Luca
>
>                ``
>               (o o)
>  ----------oOO-(_)-OOo----------
>          Luca Smeriglio
>                 Infrastructure & Operations
>     Network Architecture & Tivoli Coordination
>            NESTEC SA - Vevey Switzerland
>       TEL ++41 21 924.26.53 / FAX 924.45.89
>  -------------------------------


<Prev in Thread] Current Thread [Next in Thread>
  • Re: NV6k to TEC - resolved, Smeriglio,Luca,VEVEY,FC-SIL/INF. <=