nv-l

Re: Netview NT 5.1.1/Optivity 7.01

1999-05-20 10:49:48
Subject: Re: Netview NT 5.1.1/Optivity 7.01
From: "Boyles, Gary P" <gary.p.boyles AT INTEL DOT COM>
To: nv-l AT lists.tivoli DOT com
Date: Thu, 20 May 1999 07:49:48 -0700
You probably have to modify your \usr\OV\conf\c\oid_to_sym file,
and your \usr\OV\conf\oid_to_type file.

Basically, NetView has to be able to relate the object-id
(i.e. .1.3.6.1.4.whatever) to a specific computer-type in those
files.

Find out what OID the Bay devices puts out, and add an entry for it
in those files.

You'll probably have to go thru the discovery process again, though.

Gary Boyles

-----Original Message-----
From: Todd E. Lewis [mailto:telewis AT PROVIDENTBANKMD DOT COM]
Sent: Thursday, May 20, 1999 7:08 AM
To: NV-L AT UCSBVM.UCSB DOT EDU
Subject: Netview NT 5.1.1/Optivity 7.01


Has anyone integrated these two. What's the trick to getting netview to
correctly identify bay hubs with the right symbols? We have a couple of Bay
FDDI concentrators that appear to get correctly identified.

<Prev in Thread] Current Thread [Next in Thread>