nv-l

Re: Transcend 5.0 for AIX

1999-03-03 15:38:42
Subject: Re: Transcend 5.0 for AIX
From: Gaurav Nangia <Gaurav.Nangia AT CHASE DOT COM>
To: nv-l AT lists.tivoli DOT com
Date: Wed, 3 Mar 1999 15:38:42 -0500
Standard SNMP runs on port 161 and 162.  If one application, in this case
Transcend, uses this port first, NetView's daemons such as trapd will not
start or may have problems.  To get around, you have a few choices - (a)
change the listening port for either Transcend or NetView. (b) Install
Transcend and NetView on separate systems.  For the first one, you may call
tech support to walk you through it because I know we discussed this in
class.






"MENEZES, ALAIN" <a.menezes AT ASLK-CGER DOT BE> on 03/03/99 04:28:30 AM

Please respond to Discussion of IBM NetView and POLYCENTER Manager on
      NetView <NV-L AT UCSBVM.ucsb DOT edu>


To:   NV-L AT UCSBVM.ucsb DOT edu
cc:    (bcc: Gaurav Nangia/CHASE)
Subject:  Re: Transcend 5.0 for AIX




I'm very concerned by this possible problem : we're going to migrate to
NetView 5.1 and one of our third party apps is Transcend (version 5.1, I
believe) Can anyone confirm please !
---------------------
Alain Menezes
ASLK-CGER Services GIE                          Tel.:  +32 2 228.55.74
Rue Foss
é-aux-Loups, 48                               Fax.:  +32 2
228.83.69
1000  Bruxelles                                         Email:
a.menezes AT aslk-cger DOT be




> -----Original Message-----
> From: FITZINGER Richard [SMTP:richard.fitzinger AT CAIT.CO DOT AT]
> Sent: mardi 2 mars 1999 18:40
> To:   NV-L AT UCSBVM.UCSB DOT EDU
> Subject:      Transcend 5.0 for AIX
>
> I heard of problems running 3COM's Transcend V 5.0 on the same AIX box
> as
> NetView, in a way that Transcend runs a separate SNMP daemon and
> occupies
> port 162. Thus NetView's daemons are not able to start. The
> installation
> manual says that "Transcend NCS/U v5.0 can be installed standalone on
> a
> system running IBM/Tivoli NetView". Has somebody any experience with
> this
> subject?
>
> TYA, Richard
>
> iT-AUSTRIA
> TK/Netzwerk-Management
> Lassallestr.5
> A-1020  Wien
> Tel.: (+43 1) 21717-58944
> Fax.: (+43 1) 21717-58979
> eMail: richard.fitzinger AT it-austria DOT com


<Prev in Thread] Current Thread [Next in Thread>