nv-l

Re: "category" slot

1999-02-27 04:02:41
Subject: Re: "category" slot
From: Vladimir Petr <petr AT DATASYS DOT CZ>
To: nv-l AT lists.tivoli DOT com
Date: Sat, 27 Feb 1999 10:02:41 +0100
Hello, Joe;
I have not installed any external adapter and yet I have the tecad_ov.baroc as 
well as
tecad_hpov.baroc in the default rulebase. And I use the nvserverd adapter 
exclusively for NV events.
If you do not have these class definitions in your current rulebase how can you 
see e.g. OV* events?
You have seen the category in the nvserverd.baroc is set as OVCategoryE which 
is defined in the
tecad_ov.baroc. So I am sending the file directly to you.

Good luck,
Best regards,
Vladimir

"Prokott, Joe" wrote:
>
> Thanks Vladimir.  We are not using the secure TEC adapter, but rather
> forwarding to TEC using the NV nvserverd daemon.  There is no
> tecad_ov.baroc
> file.  There is a nvserverd.baroc file and it defines the "category"
> slot,
> but it does not define how the values are enumerated.  Could someone
> please
> post this enumeration?  Thanks,
>
> Joe Prokott - West Group
> Network Architect
> 610 Opperman Drive
> St. Paul, MN  55123
> Phone: 651-687-4536
> Fax: 651-687-6946
> E-mail: joe.prokott AT westgroup DOT com
>
> -----Original Message-----
> From: Vladimir Petr [mailto:petr AT DATASYS DOT CZ]
> Sent: Friday, February 26, 1999 12:57 AM
> To: NV-L AT UCSBVM.UCSB DOT EDU
> Subject: Re: "category" slot
>
> Hi, Joe;
> It does not match the event category but the varbind $1, i.e. the event
> source (Agent, netmon,
> netmon-related, data-collector, etc.). You can see the enumeration in
> the
> tecad_ov.baroc.
>
> HTH,
> Best regards,
> Vladimir.
>
> "Prokott, Joe" wrote:
> >
> > How does the TEC "category" slot get mapped when forwarding NV events
> to
> > TEC?  It looks like it is numeric value, but it does not seem to match
> > the
> > event "CATEGORY" values defined in the /usr/OV/conf/C/trapd.conf file.
> > Should it, or does this map to some other variable?
> >
> > Joe Prokott - West Group
> > Network Architect
> > 610 Opperman Drive
> > St. Paul, MN  55123
> > Phone: 651-687-4536
> > Fax: 651-687-6946
> > E-mail: joe.prokott AT westgroup DOT com
>
> --
> Vladimir Petr
> DATASYS s.r.o.
> mailto:petr AT datasys DOT cz
>
> --------------------------------

<Prev in Thread] Current Thread [Next in Thread>