Veritas-bu

Re: [Veritas-bu] ndmp drives down after netapp upgrade to 8.1.1RC1

2012-08-08 03:41:21
Subject: Re: [Veritas-bu] ndmp drives down after netapp upgrade to 8.1.1RC1
From: "POUSSARD-BORREL, Gilles (APX)" <gilles.poussard.external AT airbus DOT com>
To: "Iverson, Jerald" <Jerald.Iverson AT invesco DOT com>, "VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU" <VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU>
Date: Wed, 8 Aug 2012 09:41:14 +0200

Hi Jerald,

 

With 8.1RC1 and LTO4, it works well .

 

Can you try with LTO4 ?

 

Gilles.

 

De : veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] De la part de Iverson, Jerald
Envoyé : mardi 7 août 2012 17:24
À : VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU
Objet : [Veritas-bu] ndmp drives down after netapp upgrade to 8.1.1RC1

 

we have a netbackup 7.1.0.3 environment, linux master/media servers.  after upgrading 2 netapp fas3160's to 8.1.1RC1, the direct attached (thru a san switch) lto5 tape drives went down, and go back down after "up'ing" them.  1 netapp has 1 drive, the other has 2 drives, and all 3 went down and stay down.   from the first filer i see the tape drive:

 

fas3160e> ndmpd status                   

ndmpd ON.

No ndmpd sessions active.

 

fas3160e> storage show tape                

Tape Drive:         ushouebs9148a:1-9.126

Description:        IBM LTO 5 ULTRIUM

Serial Number:      F001B2B013

WWNN:               5:003:08c001:b2b013

WWPN:               5:003:08c001:b2b014

Alias Name(s):      st1 

Device State:       available

 

fas3160e> sysconfig -t

    Tape drive (ushouebs9148a:1-9.126)  IBM LTO 5 ULTRIUM

    rst1l  -  rewind device,        format is: LTO-3(ro)/4 4/800GB

    nrst1l -  no rewind device,     format is: LTO-3(ro)/4 4/800GB

    urst1l -  unload/reload device, format is: LTO-3(ro)/4 4/800GB

    rst1m  -  rewind device,        format is: LTO-3(ro)/4 8/1600GB cmp

    nrst1m -  no rewind device,     format is: LTO-3(ro)/4 8/1600GB cmp

    urst1m -  unload/reload device, format is: LTO-3(ro)/4 8/1600GB cmp

    rst1h  -  rewind device,        format is: LTO-5 1600GB

    nrst1h -  no rewind device,     format is: LTO-5 1600GB

    urst1h -  unload/reload device, format is: LTO-5 1600GB

    rst1a  -  rewind device,        format is: LTO-5 3200GB cmp

    nrst1a -  no rewind device,     format is: LTO-5 3200GB cmp

    urst1a -  unload/reload device, format is: LTO-5 3200GB cmp

 

 

from the media server:

 

ebsmd1# tpautoconf -verify fas3160e

Connecting to host "fas3160e" as user "root"...

Waiting for connect notification message...

Opening session--attempting with NDMP protocol version 4...

Opening session--successful with NDMP protocol version 4

  host supports MD5 authentication

Getting MD5 challenge from host...

Logging in using MD5 method...

Host info is:

  host name "fas3160e"

  os type "NetApp"

  os version "NetApp Release 8.1.1RC1 7-Mode"

  host id "0151736859"

Login was successful

Host supports LOCAL backup/restore

Host supports 3-way backup/restore

 

ebsmd1# tpconfig -dev_ping -drive -path /dev/nrst1a -nh fas3160e

Failed to inquiry the specified device.

 

ebsmd1# tpconfig -update -drpath -path /dev/nrst1a -nh fas3160e -asciiname adic_drv03 -drstatus UP

Device serial number for device at path /dev/nrst1a does not match drive adic_drv03.

 

ebsmd1# tpconfig -l

Device Robot Drive       Robot                    Drive       Device        Second

Type     Num Index  Type DrNum Status  Comment    Name        Path          Device Path

robot      0    -    TLD    -       -  -          -           /dev/sg11

...

  drive    -    3  hcart    4    DOWN  -          adic_drv03  /dev/nrst1a

...

 

 

does anyone else have a setup with netapp ontap 8.1.1rc1 working?  we have 12 other netapps at lower ontap versions that still work.  i think i found a compatibility chart that says it is supported.

 

thanks,

jerald

 

 

****************************************************************
Confidentiality Note: The information contained in this
message, and any attachments, may contain confidential
and/or privileged material.  It is intended solely for the
person(s) or entity to which it is addressed.  Any review,
retransmission, dissemination, or taking of any action in
reliance upon this information by persons or entities other
than the intended recipient(s) is prohibited.  If you received
this in error, please contact the sender and delete the
material from any computer.
****************************************************************

The information in this e-mail is confidential. The contents may not be disclosed or used by anyone other than the addressee. Access to this e-mail by anyone else is unauthorised.
If you are not the intended recipient, please notify Airbus immediately and delete this e-mail.
Airbus cannot accept any responsibility for the accuracy or completeness of this e-mail as it has been sent over public networks. If you have any concerns over the content of this message or its Accuracy or Integrity, please contact Airbus immediately.
All outgoing e-mails from Airbus are checked using regularly updated virus scanning software but you should take whatever measures you deem to be appropriate to ensure that this message and any attachments are virus free.
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>