Veritas-bu

Re: [Veritas-bu] Need to increase the bpstart_notify timeout wait time.

2011-06-13 10:46:15
Subject: Re: [Veritas-bu] Need to increase the bpstart_notify timeout wait time.
From: "Magsaysay, Nathan" <NMagsaysay AT medplus DOT com>
To: "BeDour, Wayne" <WBedour AT lear DOT com>, veritas-bu AT mailman.eng.auburn DOT edu
Date: Mon, 13 Jun 2011 10:46:07 -0400

This may help http://www.symantec.com/connect/forums/bpstartnotifybat-bpendnotifybat

 

Looks like an edit to bp.conf

 

Nathan Magsaysay
MedPlus, A Quest Diagnostics Company | Backup Administrator | 4690 Parkway Drive | Mason, OH 45040 USA | phone +1.513.204.2726 | nmagsaysay AT medplus DOT com | www.MedPlus.com

 

From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of BeDour, Wayne
Sent: Monday, June 13, 2011 10:41 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Need to increase the bpstart_notify timeout wait time.

 

All:

Our environment, HP-UX 11-31 currently running one master / media server on NetBackup 6.5.2.  We are running mostly unix / Linux backups and a couple windows b/u’s thrown in for good measure.

I’ve got a policy with a start and end notify script that shuts down a database and copies it to another location.  I’m getting the following error:

06/13/2011 10:23:44 - Error bpbrm (pid=30501) from client l2020: ERR - Timed out after 300 seconds waiting for bpstart_notify

06/13/2011 10:23:45 - end writing

client timed out waiting for bpstart_notify to complete (74)

Anyone know where the bpstart_notify 300 second timeout is located so I can increase it?

Thanks in advance….

Wayne BeDour

Unix System Administrator

PH: 248-447-1739

Internet: wbedour AT lear DOT com

**********************
** LEGAL DISCLAIMER **
**********************
 
This E-mail message and any attachments may contain 
legally privileged, confidential or proprietary 
information. If you are not the intended recipient(s),
or the employee or agent responsible for delivery of 
this message to the intended recipient(s), you are 
hereby notified that any dissemination, distribution 
or copying of this E-mail message is strictly 
prohibited. If you have received this message in 
error, please immediately notify the sender and 
delete this E-mail message from your computer.

 





Confidentiality Notice: The information contained in this electronic transmission is confidential and may be legally privileged. It is intended only for the addressee(s) named above. If you are not an intended recipient, be aware that any disclosure, copying, distribution or use of the information contained in this transmission is prohibited and may be unlawful. If you have received this transmission in error, please notify us by telephone (513) 229-5500 or by email (postmaster AT MedPlus DOT com). After replying, please erase it from your computer system.

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>