Veritas-bu

Re: [Veritas-bu] Solaris ADIC media server woes

2011-01-07 09:23:18
Subject: Re: [Veritas-bu] Solaris ADIC media server woes
From: "smpt" <smpt1 AT peppas DOT gr>
To: "'Preston, Douglas'" <dlpreston AT lereta DOT com>, <VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU>, <netbackup-forum AT backupcentral DOT com>
Date: Fri, 7 Jan 2011 16:23:08 +0200
What is the library model?  I2000 or i500? 

Apart of the zoning, check also the host mapping of the library. If you have
blades inside the library, check the drive mapping also.

stef

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Preston,
Douglas
Sent: Friday, January 07, 2011 3:50 PM
To: 'VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU'
Subject: Re: [Veritas-bu] Solaris ADIC media server woes

Verify the zoning on the ADIC library has the changer zoned to the server.  

Doug Preston
-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of bfcsaus
Sent: Friday, January 07, 2011 5:00 AM
To: VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU
Subject: [Veritas-bu] Solaris ADIC media server woes

Hi,

I have a problem seeing the changer and tape device on a Sun T5220 Solaris
10 server with 2 x QLC HBA's installed.

Ive logged the problem with Sun but they advise me to install to the latest
patch level etc etc which unfortunately at the moment I cannot do due to
downtime restrictions. 

Storage have told me I should be see 1 changer and 2 tapes drives

Basically I can see the ADIC Array controller from sgscan as below:

/dev/sg/c0t0l0: Disk (/dev/rdsk/c1t0d0): "SEAGATE ST914602SSUN146G"
/dev/sg/c0t1l0: Disk (/dev/rdsk/c1t1d0): "SEAGATE ST914602SSUN146G"
/dev/sg/c0tw500308c0019178b2l0: Array-controller: "ADIC    Scalar i2000"

However I should be seeing the changer and 2 tape drives.

Ive followed the notes from the admin guide (sg.install, sgbuild etc) to no
avail. I did see a thread on the same lines
(http://www.adsm.org/lists/html/Veritas-bu/2006-06/msg00065.html) which said
the LUN mapping was wrong so if anyone could assist it would be appreciated.

The days of physical tape's being attached are nearing an end I think
unfortunately.



Thanks...

+----------------------------------------------------------------------
|This was sent by steven.hoyle AT virgin DOT net via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu