At the FT Media Server you must use the specified QLogic HBAs and no other.  At 
the moment that is the 2Gb and 4Gb HBAs, no support that I have seen for 8Gb 
HBAs.  Also no support for ones on mezzanine cards or other packaging, like the 
Sun blade server modules.

We use the Sun branded Qlogic HBAs.

Device  Bus Type        
SG-XPCI1FC-QF2  PCI-X   Sun StorEdge 2 Gb Fibre Channel to PCI-X Single Port 
Host Bus Adapter
SG-XPCI2FC-QF2  PCI-X   Sun StorEdge 2 Gb Fibre Channel to PCI-X Dual Port Host 
Bus Adapter
SG-XPCI1FC-QF4  PCI-X   Sun StorageTek 4Gb FC PCI-X Single-Port Host Bus 
Adapter, QLogic
SG-XPCI2FC-QF4  PCI-X   Sun StorageTek 4Gb FC PCI-X Dual-Port Host Bus Adapter, 
QLogic
SG-XPCIE1FC-QF4 PCIe    Sun StorageTek 4Gb FC PCIe Single-Port Host Bus 
Adapter, QLogic
SG-XPCIE2FC-QF4 PCIe    Sun StorageTek 4Gb FC PCIe Dual-Port Host Bus Adapter, 
QLogic

At the SAN Client they don't seem to care what you use.  We use whatever our 
servers support, so is Emulex or Qlogic.  All we insist is that we don't share 
a port with disks or real tapes, have a dedicated port for SAN Client.

William D L Brown

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu 
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Heathe 
Yeakley
Sent: 12 July 2010 20:08
To: NetBackup Mailing List
Subject: [Veritas-bu] Fibre Transport HBAs

I've purchased some Enterprise clients and plan on using the Fibre
Transport Feature to back them up. I'm on the market for the QLogic
HBAs that my media servers need in order to backup a SAN client. From
what I've read in the NetBackup 7 FT Guide, it just says that as long
as I get a Q Logic 234x I should be fine. Is there a preferred HBA
that those of you already running FT like to use? I want to make sure
I buy the right HBAs.

Thanks.

- Heathe Kyle Yeakley
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


-----------------------------------------------------------
This e-mail was sent by GlaxoSmithKline Services Unlimited 
(registered in England and Wales No. 1047315), which is a 
member of the GlaxoSmithKline group of companies. The 
registered address of GlaxoSmithKline Services Unlimited 
is 980 Great West Road, Brentford, Middlesex TW8 9GS.
-----------------------------------------------------------

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

<Prev in Thread] Current Thread [Next in Thread>