Thanks Jeff,

 

I checked the library and found this drive did indeed need to be power cycled.  Once it powered  cycled the drive is no longer going PEND-TLD.

 

 

Doug Preston

Systems Engineer

LERETA, LLC

Client Server team

1123 Park View DR

Covina CA 91724

Phone 626-339-5221 Ext 1104

Direct Line 626-667-1447

Email  dlpreston AT lereta DOT com

 

------------------------------------------------------------------------------

NOTICE: This electronic mail transmission may constitute a communication that

is legally privileged. It is not intended for transmission to, or receipt by,

any unauthorized persons. If you have received this electronic mail

transmission in error,  notify the sender by reply e-mail so that our address

record can be corrected, then please delete it from your system without copying it.

-------------------------------------------------------------------------------

 

From: Jeff Cleverley [mailto:jeff.cleverley AT avagotech DOT com]
Sent: Wednesday, March 24, 2010 1:32 PM
To: Preston, Douglas
Subject: Re: [Veritas-bu] Tape drive constantly going PEND-TLD

 

Doug,

I can't help you from the Windows side but I've seen that type of message on my hpux master when there was a problem associated with the drive or possibly the library.  I'm guessing the library is OK if this is the only drive that is fail. 

You may check for any changes in zoning or drive replacement.  If they are fibre drives the WWN will have changed and your server may not be able to talk with it anymore.

Jeff

On Wed, Mar 24, 2010 at 1:46 PM, Preston, Douglas <dlpreston AT lereta DOT com> wrote:

NBU 6.5.3 Using SSO
ADIC I2000
14 LTO2 drives

Master server and 4 Media servers are Windows 2003 all running NBU 6.5.3
Using Veritas drivers on Master and all Media servers.

I have one of my drives in a state of PEND-DLT
With no jobs running on any server.

I have tried removing all drives from NBU,
removing the Library from NBU,
stopping all services,
removing PEMPERSIST2.
Removing all files from \program files\veritas\netbackup\db\media\drives\
Removing all files from \program files\veritas\netbackup\db\media\tpreq\
Removing all files from \program files\veritas\volmgr\misc\



Restarting services,
Recreating the library
Recreating the drives
Inventorying the library


Wait 5 minutes and the drive goes back to PEND-TLD

Anyone have any ideas oh now to fix this issue?


Doug Preston
Systems Engineer
LERETA, LLC
Client Server team
1123 Park View DR
Covina CA 91724
Phone 626-339-5221 Ext 1104
Direct Line 626-667-1447
Email  dlpreston AT lereta DOT com

------------------------------------------------------------------------------
NOTICE: This electronic mail transmission may constitute a communication that
is legally privileged. It is not intended for transmission to, or receipt by,
any unauthorized persons. If you have received this electronic mail
transmission in error,  notify the sender by reply e-mail so that our address
record can be corrected, then please delete it from your system without copying it.
-------------------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu




--
Jeff Cleverley
Unix Systems Administrator
4380 Ziegler Road
Fort Collins, Colorado 80525
970-288-4611

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>