Good to see we are not the only ones having these issue with Solaris and tape drives. IMHO Solaris does a really bad job with tapes and robots. It really shouldn’t be this difficult. HP-UX makes it much easier to config and diagnose problems…Just my 2 cents…..

 


From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Dushyant Mehta
Sent: Thursday, February 11, 2010 3:18 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Robot disappeared from OS

 

All,

We have STK L180 tape library connected to a Solaris 10 master/media server.Until 3 days back we were able to see tape drives and robots  and now the robot has disappeared.  Initially when we were seeing the robot, we were not able to configure it in netbackup. when we did a scan -changer on that robot it used to report "0" drives and "0" slots whereas the library has 6 drives and 84 slots. To fix that problem Symantec suggested rebuilding the sg driver and told me to remove everything from /dev/rmt/*cbn and /dev/sg directories. After doing that and rebooting the master with a reconfiguration we lost the robot.

Everything is connected to McData switch and on the switch side I see all the ports logging in without any error.However when i run cfgadm -al it shows this for the robot wwn :

c3::500104f0005859c8        unavailable      connected     configured      failed

I have been working with Symantec and Sun and both are unable to identify the problem.

I have tried resetting hba, resetting the robot, rebooting the complete library etc but still sgscan and scan -changer does not show the robot.

I have 2 questions :

1) When the robot does not report on correct info in scan -changer command, what can be the issue ?
2) What can we do to see the robot back ?

We are on NBU 6.0 MP6, with Solaris 10 on master, Emulex HBA, Mc Data Switch, STK L180 tape library.

Thanks,

Dushyant Mehta


The information contained in this email message and its attachments is intended only for the private and confidential use of the recipient(s) named above, unless the sender expressly agrees otherwise. Transmission of email over the Internet is not a secure communications medium. If you are requesting or have requested the transmittal of personal data, as defined in applicable privacy laws by means of email or in an attachment to email you must select a more secure alternate means of transmittal that supports your obligations to protect such personal data. If the reader of this message is not the intended recipient and/or you have received this email in error, you must take no action based on the information in this email and you are hereby notified that any dissemination, misuse, copying, or disclosure of this communication is strictly prohibited. If you have received this communication in error, please notify us immediately by email and delete the original message.