Re: [Veritas-bu] Any gotchas with 10 GB Ethernet?

2010-02-02 02:24:55
Subject: Re: [Veritas-bu] Any gotchas with 10 GB Ethernet?
From: "William Brown" <william.d.brown AT gsk DOT com>
To: "veritas-bu AT mailman.eng.auburn DOT edu" <veritas-bu AT mailman.eng.auburn DOT edu>
Date: Tue, 2 Feb 2010 08:24:22 +0100
This is what we use, though it is not special to 10GbE; I've no doubt many 
people will have their own schemes.  It's from a script that checks settings 
against our design:

        NETWORK TUNING PARAMETERS


        TCP parameters:

        tcp_wscale_always:            current:       1  recommended:       1
        tcp_tstamp_if_wscale:         current:       1  recommended:       1
        tcp_xmit_hiwat:               current: 1048576  recommended: 1048576
        tcp_recv_hiwat:               current: 1048576  recommended: 1048576
        tcp_cwnd_max:                 current: 2097152  recommended: 2097152
        tcp_max_buf:                  current: 4194304  recommended: 4194304
        tcp_time_wait_interval:       current:   60000  recommended:   60000
        tcp_conn_req_max_q:           current:    8192  recommended:    8192


        Sendpipes & Recvpipes:

        route <x.x.x.x>  recvpipe:  current: 1048576  recommended: 1048576
        route <x.x.x.x>  sendpipe:  current: 1048576  recommended: 1048576

I'd say the hiwat settings are the most important, and tcp_cwnd_max and 
tcp_max_buf must be raised to allow for that.  We are also implementing Jumbo 
Frames which in testing made about 60-80% increase in throughput using iperf.  
Slightly harder to test with NetBackup as more moving parts like disks 
involved, and for many clients we cannot set it as we don't have a separate 
backup LAN, and some applications don't want to try it.

William D L Brown


-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu 
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Tschida, 
Tom (STP)
Sent: 01 February 2010 22:29
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Any gotchas with 10 GB Ethernet?

Hello All,

We are in the process of implementing 2 new Solaris media servers with
10 GB Ethernet.  Are there any gotchas on the OS side or the NetBackup
side I should be aware of?  Any buffer settings we need to tweak or new
touch files, etc?

Thanks in advance.

Tom Tschida
Boston Scientific
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


-----------------------------------------------------------
This e-mail was sent by GlaxoSmithKline Services Unlimited 
(registered in England and Wales No. 1047315), which is a 
member of the GlaxoSmithKline group of companies. The 
registered address of GlaxoSmithKline Services Unlimited 
is 980 Great West Road, Brentford, Middlesex TW8 9GS.
-----------------------------------------------------------

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

<Prev in Thread] Current Thread [Next in Thread>