Well I thought that but see a bit above:

 

\\.\Tape1, drive serial number HU10606CNF, expected serial number HU10606CNF

 

 

That’s the drive serial number.

 

William D L Brown

 

From: Preston, Douglas [mailto:dlpreston AT lereta DOT com]
Sent: 15 January 2010 15:06
To: William Brown; VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] LTO tape label / sequence?

 

That serial number is actually the drive serial number.  It will freeze media if it gets any error or non matched info

 

Doug Preston

Systems Engineer

LERETA, LLC

Client Server team

1123 Park View DR

Covina CA 91724

Phone 626-339-5221 Ext 1104

Email  dlpreston AT lereta DOT com

 

------------------------------------------------------------------------------

NOTICE: This electronic mail transmission may constitute a communication that

is legally privileged. It is not intended for transmission to, or receipt by,

any unauthorized persons. If you have received this electronic mail

transmission in error,  notify the sender by reply e-mail so that our address

record can be corrected, then please delete it from your system without copying it.

-------------------------------------------------------------------------------

 

From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of William Brown
Sent: Friday, January 15, 2010 5:05 AM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] LTO tape label / sequence?

 

I was quite surprised to find that NetBckup is not just looking at the tape label, but also what I think is the cartridge serial number with LTO.  I guess that comes from the LTO-CM.  This is 6.5.4

 

This happened on a Windows Master/Media server in our test lab:

 

20:00:48.922 [3908.1968] <2> openTpreqFile: tpreq_file: D:\Program Files\VERITAS\NetBackup\db\media\tpreq\drive_Drive1, serial_num: HU10606CNF

20:00:48.922 [3908.1968] <2> get_drive_path: SCSI coordinates {5,1,1,3}, dos_path \\.\Tape1, pnp_path \\?\scsi#sequential&ven_hp&prod_ultrium_3-scsi&rev_g54w#4&2b40ae32&0&113#{53f5630b-b6bf-11d0-94f2-00a0c91efb8b}

20:00:48.922 [3908.1968] <2> check_serial_num: serial number match for drive with SCSI coordinates {5,1,1,3}, dos_path \\.\Tape1, drive serial number HU10606CNF, expected serial number HU10606CNF

20:00:48.954 [3908.1968] <2> init_tape: \\.\Tape1 (SCSI coordinates {5,1,1,3}) configured with blocksize 0

20:00:48.954 [3908.1968] <2> init_tape: \\.\Tape1 (SCSI coordinates {5,1,1,3}) has compression enabled

20:00:48.969 [3908.1968] <2> io_open: SCSI RESERVE

20:00:49.391 [3908.1968] <2> manage_drive_attributes: report_attr, fl1 0x00000429, fl2 0x00000004

20:00:49.391 [3908.1968] <4> manage_drive_attributes: expected manufacturer [HP], reported [HP]

20:00:49.391 [3908.1968] <4> manage_drive_attributes: expected serial number [E63YABQ480], reported [1120653908]

20:00:49.391 [3908.1968] <2> send_MDS_msg: MEDIADB 1 1534 000013 4000113 *NULL* 20 1262980800 0 0 0 0 0 0 3 2 0 17 1024 0 0 0

20:00:49.391 [3908.1968] <16> manage_drive_attributes: FREEZING media id 000013, Medium identifiers do not match

20:00:49.391 [3908.1968] <2> io_close: closing D:\Program Files\VERITAS\NetBackup\db\media\tpreq\drive_Drive1, from bptm.c.18660

2

 

So I’d suggest, don’t reuse barcodes.

 

William D L Brown

 

From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of J.Keating AT tachi-s DOT com
Sent: 14 January 2010 21:12
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] LTO tape label / sequence?

 


Hello,

The question of "should we be paying particular attention of tape labels" question reared it's ugly head for me once again and I can't remember the answer.

Am I correct to believe that NBU won't import or confuse itself or the database if we should put a tape in the robot which has the same label as a tape that's has already been written too and cataloged?
And, should I be ordering labels with an existing sequence?


Regards,
John Keating
Information Technology
Tachi-S Engineering U.S.A. Inc.

-----------------------------------------------------------
This e-mail was sent by GlaxoSmithKline Services Unlimited 
(registered in England and Wales No. 1047315), which is a 
member of the GlaxoSmithKline group of companies. The 
registered address of GlaxoSmithKline Services Unlimited 
is 980 Great West Road, Brentford, Middlesex TW8 9GS.
-----------------------------------------------------------

-----------------------------------------------------------
This e-mail was sent by GlaxoSmithKline Services Unlimited 
(registered in England and Wales No. 1047315), which is a 
member of the GlaxoSmithKline group of companies. The 
registered address of GlaxoSmithKline Services Unlimited 
is 980 Great West Road, Brentford, Middlesex TW8 9GS.
-----------------------------------------------------------

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu