Veritas-bu

Re: [Veritas-bu] NetApp and Scaler i2000

2009-05-22 10:08:33
Subject: Re: [Veritas-bu] NetApp and Scaler i2000
From: Randy Doering <rdoering2 AT verizon DOT net>
To: "Spearman, David" <spe08 AT co.henrico.va DOT us>, "veritas-bu AT mailman.eng.auburn DOT edu" <veritas-bu AT mailman.eng.auburn DOT edu>
Date: Fri, 22 May 2009 07:05:24 -0700 (PDT)
On the NetApp, do the tape drives show up with the "sysconfig" command?
 
If not, you may need to offline/online the specific FC Host Adapter. See the fcadmin command after "priv set advanced".
 
Randy

 


From: "Spearman, David" <spe08 AT co.henrico.va DOT us>
To: "veritas-bu AT mailman.eng.auburn DOT edu" <veritas-bu AT mailman.eng.auburn DOT edu>
Sent: Friday, May 22, 2009 9:47:08 AM
Subject: [Veritas-bu] NetApp and Scaler i2000

I am trying to get ndmp running to our NetApp. (everything is working on ndmp to Celera) I have fc zoned the Scaler library to the NetApp and the Scaler seems to be happy enough with zones and lun mapping. However the NetApp is not playing nice. I have been through the Ontap 7.3 tape backup guide but no matter what I do the NetApp refuses to recognize the library and tape units. Anyone know where that last button to be pushed lives? I can three way just fine with my 6.5.3 system.

David Spearman
County of Henrico, Va.
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>