Veritas-bu

Re: [Veritas-bu] Strange problem after changing storage unit.

2009-03-05 10:04:53
Subject: Re: [Veritas-bu] Strange problem after changing storage unit.
From: "Stafford, Geoff" <GStafford AT barclaycardus DOT com>
To: "Dave Markham" <dave.markham AT fjserv DOT net>, veritas-bu AT mailman.eng.auburn DOT edu
Date: Thu, 5 Mar 2009 09:45:02 -0500

Set your catalog to backup the vm.conf file so when you restore the catalog it brings that file back.  Right click catalog/configure catalog backup/files tab/add path to vm.conf.

 

 

Geoff Stafford

Barclaycard US

Data Protection Team Manager

office:

mobile:

 

 

 

Message: 13

Date: Thu, 05 Mar 2009 14:06:28 +0000

From: Dave Markham <dave.markham AT fjserv DOT net>

Subject: Re: [Veritas-bu] Strange problem after changing storage unit.

To: Justin Piszcz <jpiszcz AT lucidpixels DOT com>

Cc: "veritas-bu AT mailman.eng.auburn DOT edu"

      <veritas-bu AT mailman.eng.auburn DOT edu>

Message-ID: <49AFDC64.5090802 AT fjserv DOT net>

Content-Type: text/plain; charset=ISO-8859-1; format=flowed

 

Dude i totally didn't read to the bottom of your email.

 

Thats exactly what has happened. Its now working.

 

Fantastic.  What a star.

 

How would i have found that out? Dear me.

 

Cheers

 

 

Justin Piszcz wrote:

> On Thu, 5 Mar 2009, Dave Markham wrote:

> 

>  

>> Netbackup 5.0MP7 running on Solaris with SL24

>> 

>> Guys i got a bit of weird issue i wondered if anyone could shed some

>> light on.

>> 

>> A customer is changing from an L1000 to an SL24, but wants to have

>> the L1000 configured also for historic restores until they expire.

>> 

>> In a test bed on same server hardware (e220r) i have built a fresh OS

>> using Sol9 09/05 (needed mpt driver for new Ultra320 HBA installed),

>> cabled up the SL24 with 2 x LTO3 drives in it.

>> 

>> - I installed NBU and patched to MP7 as the existing install is.

>> - Then got the catalogues over  and did a bprecover -r -dpath <path

>> to cats>

>> - This recovered everything including the old L1000 storage unit.

>> - I removed the robot and drives using tpconfig, vmadm.

>> - I then configured the new SL24 unit and did an inventory on which

>> brought in the new LTO3 tapes and put them as scratch (as by barcode

>> rules said to do).

>> - I can see all my old media in volume group ---  and all my new

>> media in 00_000_TLD

>> - I have left the L1000 storage unit configured in NBU as i want to

>> connect it later, where i will add using correct path etc.

>> - I have changed policies to use the SL24 storage unit

>> 

>> Now the problem is when i try and run a backup it is failing with

>> status

>> 96 no media available. I can't understand why as i have new media in

>> which is scratch.

>> 

>> Anyone any ideas? Do i need to remove the L1000 storage unit completely?

>> Is something hidden somewhere i need to change?

>> 

>> Cheers

>> 

>> _______________________________________________

>> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu

>> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

>> 

>>    

> 

> 1. So you took the tapes from the L1000 and put them into an SL24?

> 2. I am assuming the media servers did not change?

> 3. Did the drve tapes stay the same?

> 4. Did you inventory the library and make sure the media is scratch?

> 5. Is the barcode reader in the new robot inventorying the tapes the same

>     way as the old one?

> 

> --

> 

> Wait, I know, at least in NetBackup 5.1x, you've hit the catalog restore bug!

> The bug is this: After you recover the catalog it de-activates your

> scratch pool!

> 

> Right click the Scratch volume pool, and select [x] Enable/Scratch Pool!

> 

> This got me a few times as well :)

> 

> Justin.

> 

> _______________________________________________

> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu

> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

> 

> 

>  

 

 

 

 

 

 




_______________________________________________________

Barclays
www.barclaycardus.com
_______________________________________________________

This e-mail and any files transmitted with it may contain confidential and/or proprietary information. It is intended solely for the use of the individual or entity who is the intended recipient. Unauthorized use of this information is prohibited. If you have received this in error, please contact the sender by replying to this message and delete this material from any system it may be on.
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu