Veritas-bu

Re: [Veritas-bu] Moving to new master

2008-12-02 04:19:37
Subject: Re: [Veritas-bu] Moving to new master
From: "Clooney, David" <david.clooney AT bankofamerica DOT com>
To: "WEAVER, Simon (external)" <simon.weaver AT astrium.eads DOT net>, VERITAS-BU AT mailman.eng.auburn DOT edu
Date: Tue, 02 Dec 2008 09:07:06 +0000
My advice would be to migrate to a unix master.....

 
David Clooney
Enterprise Storage Services
 
Internal X66059
External +44 20 8760 6059
david.clooney AT bankofamerica DOT com
 

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of WEAVER,
Simon (external)
Sent: 26 November 2008 06:13
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Moving to new master


Sounds like some sort of inconsistency.

Not sure what your plan is to move to a new master - Are you using
bprecover to restore everything back to the new platform? Ideally, it's
be better to restore everything to the new hardware, using the same
OS/NetBackup revisions from the previous master.

Either that, or delete and rebuild the global database. As I said, to
me; sounds like something is out of sync.

There is a section in the NetBackup Disaster Recovery plan about using
the bprecover and restoring the catalogs. Remember, retaining the same
IP / Server Name / OS / NetBackup / Patch Level is essential to the
success of this.

Simon 

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of
venkatesh111
Sent: Tuesday, November 25, 2008 11:16 PM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Moving to new master


Hi All,

we are planing to move our netbackup master server to newely built
Windows 2003 box

old master windows - 2000

veritas version : 5.0MP3

 

last time we tried this and when trying to configure storage devices
none of the tape drives were detected for master (all the drives are
visible from OS level)and it throwed an error, 

"could not get device configaration, cannot configure devices, see
troubleshoting guide for details (44) "

 "device discovery failed on host <Master-server>"

 

tpautoconf -a gives "Fatal Global Database consistancy error"

 

 

any idea what is going wrong here any tech note that i can refer in this
situation ?

+----------------------------------------------------------------------
|This was sent by venkatesh111 AT gmail DOT com via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from
disclosure.
If you are not the intended recipient, please notify the sender
immediately, do not copy this message or any attachments and do not use
it
for any purpose or disclose its content to any person, but delete this
message and any attachments from your system. Astrium disclaims any and
all
liability if this email transmission was virus corrupted, altered or
falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259
REGISTERED OFFICE:-
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu



Notice to recipient:
The information in this internet e-mail and any attachments is confidential and 
may be privileged. It is intended solely for the addressee. If you are not the 
intended addressee please notify the sender immediately by telephone. If you 
are not the intended recipient, any disclosure, copying, distribution or any 
action taken or omitted to be taken in reliance on it, is prohibited and may be 
unlawful.

When addressed to external clients any opinions or advice contained in this 
internet e-mail are subject to the terms and conditions expressed in any 
applicable governing terms of business or client engagement letter issued by 
the pertinent Bank of America group entity.

If this email originates from the U.K. please note that Bank of America, N.A., 
London Branch and Banc of America Securities Limited are authorised and 
regulated by the Financial Services Authority.  For all U.K. corporate 
disclosures, please refer to www.bankofamerica.com/ukcompanies

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

<Prev in Thread] Current Thread [Next in Thread>