Re: [Veritas-bu] Moving to new master

2008-11-26 02:04:47
Subject: Re: [Veritas-bu] Moving to new master
From: Anders Thome <anders.thome AT ementor DOT no>
To: "VERITAS-BU AT mailman.eng.auburn DOT edu" <VERITAS-BU AT mailman.eng.auburn DOT edu>
Date: Wed, 26 Nov 2008 07:52:00 +0100
You could on the old master: do one catalogbackup, then delete all the devices,
and do second catalogbackup(to disk.
And use the last catalogbackup for recovery on the new master.. and then set up 
devices like it should be.

I've done this successfully on an numerous sites. Not from W2000 to W2003 
though...

Anders

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu 
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of WEAVER, 
Simon (external)
Sent: 26. november 2008 07:13
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Moving to new master


Sounds like some sort of inconsistency.

Not sure what your plan is to move to a new master - Are you using
bprecover to restore everything back to the new platform? Ideally, it's
be better to restore everything to the new hardware, using the same
OS/NetBackup revisions from the previous master.

Either that, or delete and rebuild the global database. As I said, to
me; sounds like something is out of sync.

There is a section in the NetBackup Disaster Recovery plan about using
the bprecover and restoring the catalogs. Remember, retaining the same
IP / Server Name / OS / NetBackup / Patch Level is essential to the
success of this.

Simon 

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of
venkatesh111
Sent: Tuesday, November 25, 2008 11:16 PM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Moving to new master


Hi All,

we are planing to move our netbackup master server to newely built
Windows 2003 box

old master windows - 2000

veritas version : 5.0MP3

 

last time we tried this and when trying to configure storage devices
none of the tape drives were detected for master (all the drives are
visible from OS level)and it throwed an error, 

"could not get device configaration, cannot configure devices, see
troubleshoting guide for details (44) "

 "device discovery failed on host <Master-server>"

 

tpautoconf -a gives "Fatal Global Database consistancy error"

 

 

any idea what is going wrong here any tech note that i can refer in this
situation ?

+----------------------------------------------------------------------
|This was sent by venkatesh111 AT gmail DOT com via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure.
If you are not the intended recipient, please notify the sender
immediately, do not copy this message or any attachments and do not use it
for any purpose or disclose its content to any person, but delete this
message and any attachments from your system. Astrium disclaims any and all
liability if this email transmission was virus corrupted, altered or
falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259
REGISTERED OFFICE:-
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

<Prev in Thread] Current Thread [Next in Thread>