Veritas-bu

Re: [Veritas-bu] Media Tape lifespan

2007-12-17 18:11:14
Subject: Re: [Veritas-bu] Media Tape lifespan
From: "Curtis Preston" <cpreston AT glasshouse DOT com>
To: "Josef Weingand" <WEINGAND AT de.ibm DOT com>, "Jackson, Todd" <c-todd.jackson AT invitrogen DOT com>
Date: Mon, 17 Dec 2007 17:54:36 -0500

What’s you reference for these nums?

 

---

W. Curtis Preston

Backup Blog @ www.backupcentral.com

VP Data Protection, GlassHouse Technologies


From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Josef Weingand
Sent: Monday, December 17, 2007 8:22 AM
To: Jackson, Todd
Cc: WEAVER, Simon (external); veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Media Tape lifespan

 


The LTO Specs says:
Long-length durability:         260 full file passes
Short-length durability:        5000 load, unload, and initialization cycles
Limited lifetime warranty: ?
Archive live:                up to 30 years

Some vendors gives some enhanced specs, like IBM LTO cartridges:
Long-length durability         300 full file passes
Short-length durability         20 000 short section durability passes
Load/unload                20 000 load/unload cycles
Limited lifetime warranty 5 years (manufacturing defects only)
Archive live:                up to 30 years

Mit freundlichen Grüßen / Kind regards
Josef Weingand
Senior IT Specialist
Technical Sales Systems Storage

Mobil +49 171 55 26 783 - Homeoffice Tel. +49 8845 757421
Fax +49 171 13 5526783
email: weingand AT de.ibm DOT com
SMS/eMail: 01715526783 AT t-d1-sms DOT de

IBM Deutschland GmbH
Vorsitzender des Aufsichtsrats: Hans Ulrich Maerki
Geschäftsführung: Martin Jetter (Vorsitzender), Rudolf Bauer, Christian Diedrich, Christoph Grandpierre, Matthias Hartmann, Thomas Fell, Michael Diemer
Sitz der Gesellschaft: Stuttgart
Registergericht: Amtsgericht Stuttgart, HRB 14562 WEEE-Reg.-Nr. DE 99369940


From:

"Jackson, Todd" <c-todd.jackson AT invitrogen DOT com>

To:

"WEAVER, Simon \(external\)" <simon.weaver AT astrium.eads DOT net>, <veritas-bu AT mailman.eng.auburn DOT edu>

Date:

14.12.2007 16:27

Subject:

Re: [Veritas-bu] Media Tape lifespan

 





Yes it does help. Currently this concern is for auditing purposes for a tape destruction plan.
Normally I would use until it dies but here it is regulatory needs. I was thinking of setting
a lifespan between 500-1000 mounts. NB has it set to stop using after 5000 mounts but I need
a decent number and wondering if 1000 is expecting a bit much for audits.
 


From: WEAVER, Simon (external) [mailto:simon.weaver AT astrium.eads DOT net]
Sent:
Friday, December 14, 2007 10:20 AM
To:
Jackson, Todd; veritas-bu AT mailman.eng.auburn DOT edu
Subject:
RE: [Veritas-bu] Media Tape lifespan


Well unless you get problems, then continue to use them where possible.
 
As soon as I get read / write issues, then its time to throw away....
 
Lifespans of tapes (especially LTO) isnt straight forward as it may seem. I think the estimate life is 20 - 30 years. But by then, we would be on LTO17 or something like that!
 
Also, manufacturer of tape may come into question. As a guess, if the tape is using 300+ mounts, then your getting good serious use out of the tape.
 
Hope this may help....
Simon
-----Original Message-----
From:
veritas-bu-bounces AT mailman.eng.auburn DOT edu [
mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Jackson, Todd
Sent:
Friday, December 14, 2007 3:16 PM
To:
veritas-bu AT mailman.eng.auburn DOT edu
Subject:
[Veritas-bu] Media Tape lifespan

How long should you use a media tape such as Quantum LTO2 tapes?
 
There is no standard concerning this but I have read a few different opinions.
I would think mounts would be more important then writes because reading
a tape can be just a strenuous to the tape as writing to the tape.
 
If anyone has something in place for tape destruction please share

This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure.
If you are not the intended recipient, please notify the sender
immediately, do not copy this message or any attachments and do not use it
for any purpose or disclose its content to any person, but delete this
message and any attachments from your system. Astrium disclaims any and all
liability if this email transmission was virus corrupted, altered or
falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259
REGISTERED OFFICE:-
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu