[Veritas-bu] Serious master issue...
2007-02-14 14:42:37
Subject: |
[Veritas-bu] Serious master issue... |
From: |
john_rickus at dofasco.ca (john_rickus AT dofasco DOT ca) |
Date: |
Wed, 14 Feb 2007 14:42:37 -0500 |
We had a similar problem with our master server ( rp4440) that backs up
oracle databases. Found that the rman script *.rcv had the filesperset
set too low ( we had turned it down from 20 to 5 for the archive logs),
causing hundreds of backup images. This resulted in the disk I/O being
high when the cleanup ran, and loads of bpdbm processes.
John Rickus
Storage Analyst
Dofasco Inc.
905-548-7200 ext. 6004
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20070214/91465c15/attachment.html
|
|
|