Veritas-bu

[Veritas-bu] Media type confusion / fixed

2006-11-29 18:40:27
Subject: [Veritas-bu] Media type confusion / fixed
From: ddunham at taos.com (Darren Dunham)
Date: Wed, 29 Nov 2006 15:40:27 -0800 (PST)
> But what if you are using the same series of barcodes for different
> media? Is this a no-no and there is no work around?

> I have the same issue where I inventory a robot with LTO drive/media
> and it defaults to DLT3 and creates a new volume group. I have to use
> the GUI Configure Volumes to correct them as HCART2 and then manually
> move them from the Netbackup pool they had been put in to the scratch
> pool.

Unless you can tell which is which by looking at the barcode, I don't
know any way to get the system to do this automatically.  The barcode
rules appear to be shared by all robots on a particular media server.
If you could separate the robots to different media servers, then you
could put different rules on each.

-- 
Darren Dunham                                           ddunham at taos.com
Senior Technical Consultant         TAOS            http://www.taos.com/
Got some Dr Pepper?                           San Francisco, CA bay area
         < This line left intentionally blank to confuse you. >

<Prev in Thread] Current Thread [Next in Thread>