You have a bad robot controller board in your L700. If you remove the side
panel opposite the media, you will see 2 large controller boards. The upper on
has your SCSI communication channels. I would say that you would see some RED
leds on the top row of status LED's.
If the library does not correctly recognize the drives, your OS or NB does not
have a remote chance of recognizing it.
You should be able to go to the L700 control panel and list the SCSI settings
with no difficulty.
If you don't have a maintenance contract on your L700, you could set the robot
control board to use the tape drive SCSI ID's instead of the robot set ID's.
Bobby.
From: Mike Jackson <mike.m.jackson at ca.mci.com>
Date: 2006/11/06 Mon AM 11:45:20 EST
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] Serious problem - DLT7000 tape drives gone "not
functional"
Hello all,
We're running a Solaris w/ NetBackup 5.0 master server environment with
a SCSI attached StorageTek L700 library with eight DLT7000 drives. We
ran into an "event" the other night which cleared the L700 configuration
which reset all of the drive SCSI ID's to Invalid. I manually
reconfigured the SCSI ID's 00 through 08 (skipping 07 which we cannot
use). SGSCAN sees the drives but when I try robtest or run manual
backups the environment goes crazy and DOWN's all the drives. I've got
a support ticket opened with StorageTek but at this point they're not
sure what the problem could be. The LCD display on the L700 library
says "NOT FUNCTIONAL" for all the drives even after a reboot.
Here's some information from sgscan / tpconfig && robtest:
[nb-master-01:ROOT](~): sgscan
..
/dev/sg/c10t5l0: Changer: "STK L700"
..
/dev/sg/c2t0l0: Tape (/dev/rmt/0): "QUANTUM DLT7000"
/dev/sg/c2t1l0: Tape (/dev/rmt/1): "QUANTUM DLT7000"
/dev/sg/c4t2l0: Tape (/dev/rmt/2): "QUANTUM DLT7000"
/dev/sg/c4t3l0: Tape (/dev/rmt/3): "QUANTUM DLT7000"
/dev/sg/c6t4l0: Tape (/dev/rmt/4): "QUANTUM DLT7000"
/dev/sg/c6t5l0: Tape (/dev/rmt/5): "QUANTUM DLT7000"
/dev/sg/c8t6l0: Tape (/dev/rmt/6): "QUANTUM DLT7000"
[nb-master-01:ROOT](~):
[nb-master-01:ROOT](~): tpconfig -l
Device Robot Drive Robot Drive
Device Second
Type Num Index Type DrNum Status Comment Name Path
Device Path
robot 0 - TLD - - - -
/dev/sg/c10t5l0
drive - 0 dlt 3 UP - QUANTUMDLT70003
/dev/rmt/2cbn
drive - 1 dlt 4 UP - QUANTUMDLT70004
/dev/rmt/3cbn
drive - 2 dlt 5 UP - QUANTUMDLT70005
/dev/rmt/4cbn
drive - 3 dlt 6 UP - QUANTUMDLT70006
/dev/rmt/5cbn
drive - 4 dlt 7 UP - QUANTUMDLT70007
/dev/rmt/6cbn
drive - 5 dlt 1 UP - QUANTUMDLT70001
/dev/rmt/0cbn
drive - 7 dlt 2 UP - QUANTUMDLT70002
/dev/rmt/1cbn
Robot selected: TLD(0) robotic path = /dev/sg/c10t5l0
Invoking robotic test utility:
/usr/openv/volmgr/bin/tldtest -r /dev/sg/c10t5l0 -d1 /dev/rmt/0cbn -d2
/dev/rmt/1cbn -d3 /dev/rmt/2cbn -d4 /dev/rmt/3cbn -d5 /dev/rmt/4cbn -d6
/dev/rmt/5cbn -d7 /dev/rmt/6cbn
Opening /dev/sg/c10t5l0
MODE_SENSE complete
Enter tld commands (? returns help information)
s d
drive 1 (addr 500) access = 0 Contains Cartridge = no
Sense code = 0x40, Code qualifier = 0x2
SCSI ID from drive 1 is 0
drive 2 (addr 501) access = 0 Contains Cartridge = no
Sense code = 0x40, Code qualifier = 0x2
SCSI ID from drive 2 is 1
drive 3 (addr 502) access = 0 Contains Cartridge = no
Sense code = 0x40, Code qualifier = 0x2
SCSI ID from drive 3 is 2
drive 4 (addr 503) access = 0 Contains Cartridge = no
Sense code = 0x40, Code qualifier = 0x2
SCSI ID from drive 4 is 3
drive 5 (addr 504) access = 0 Contains Cartridge = no
Sense code = 0x40, Code qualifier = 0x2
SCSI ID from drive 5 is 4
drive 6 (addr 505) access = 0 Contains Cartridge = no
Sense code = 0x40, Code qualifier = 0x2
SCSI ID from drive 6 is 5
drive 7 (addr 506) access = 1 Contains Cartridge = yes
Source address = 1510 (slot 511)
Barcode = 000610
SCSI ID from drive 7 is 6
<< Press return to continue, or q and return to stop >>
drive 8 (addr 507) access = 1 Contains Cartridge = no
SCSI ID from drive 8 is 8
READ_ELEMENT_STATUS complete
Here's the logs when a backup is attempted:
Nov 6 11:16:51 nb-master-01 tldcd[7433]: TLD(0) key = 0x4, asc = 0x40,
ascq = 0x2, UNKNOWN ERROR, KEY: 0x04, ASC: 0x40, ASCQ: 0x02
Nov 6 11:16:51 nb-master-01 tldcd[7433]: TLD(0) Move_medium error
Nov 6 11:16:51 nb-master-01 tldcd[7439]: TLD(0) cannot clear drive 4
error, drive asc=0x40, ascq=0x2
Nov 6 11:16:51 nb-master-01 tldcd[7441]: TLD(0) cannot clear drive 3
error, drive asc=0x40, ascq=0x2
tpconfig -lNov 6 11:16:51 nb-master-01 tldcd[7445]: TLD(0) cannot clear
drive 5 error, drive asc=0x40, ascq=0x2
Nov 6 11:16:51 nb-master-01 tldd[7015]: TLD(0) drive 7 (device 4) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:51 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:51 nb-master-01 tldcd[7447]: TLD(0) cannot clear drive 6
error, drive asc=0x40, ascq=0x2
Nov 6 11:16:51 nb-master-01 tldd[7015]: TLD(0) drive 4 (device 1) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:51 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:51 nb-master-01 tldd[7015]: TLD(0) drive 3 (device 0) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:51 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:51 nb-master-01 tldd[7015]: TLD(0) drive 5 (device 2) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:51 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:51 nb-master-01 tldd[7015]: TLD(0) drive 6 (device 3) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:51 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:52 nb-master-01 tldcd[7457]: TLD(0) cannot clear drive 1
error, drive asc=0x40, ascq=0x2
Nov 6 11:16:52 nb-master-01 tldd[7015]: TLD(0) drive 1 (device 5) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:52 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:52 nb-master-01 tldcd[7466]: TLD(0) cannot clear drive 2
error, drive asc=0x40, ascq=0x2
Nov 6 11:16:52 nb-master-01 ltid[6960]: Request for media ID 000610 is
being rejected because the media appears to be unmountable
Nov 6 11:16:52 nb-master-01 tldd[7015]: TLD(0) bad media suspected;
configuring device 4 back UP
Nov 6 11:16:54 nb-master-01 tldcd[7476]: TLD(0) key = 0x5, asc = 0x3a,
ascq = 0x0, MEDIUM NOT PRESENT
Nov 6 11:16:54 nb-master-01 tldcd[7476]: TLD(0) Move_medium error
Nov 6 11:16:54 nb-master-01 tldd[7015]: TLD(0) drive 7 (device 4) is
being DOWNED, status: Unable to SCSI unload drive
Nov 6 11:16:54 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Nov 6 11:16:55 nb-master-01 tldcd[7484]: TLD(0) cannot clear drive 2
error, drive asc=0x40, ascq=0x2
Nov 6 11:16:55 nb-master-01 tldd[7015]: TLD(0) drive 2 (device 7) is
being DOWNED, status: Robotic mount failure
Nov 6 11:16:55 nb-master-01 tldd[7015]: Check integrity of the drive,
drive path, and media
Any help would be GREATLY appreciated!
Thanks!
- Mike
_______________________________________________
Veritas-bu maillist - Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
Bobby Williams
2205 Peterson Drive