I was hoping to pick someone's brain. I am busy running a NDMP restore on
Netbackup 5.1 MP3 on windows. It runs for about 2 hours and restores +/- 4Gb
worth of data. The total restore is a lot bigged than that. It then fails with
and error code 5. Here is the bptm logs. I must admite that we are doing the
restore at an DR site, so i'm not 100% that all the settings in NetBackup is
the same at both sites. The NDMP machines are both EMC Celerra's and are the
same model and firmware version. Is there something more that i can
check/change before i log a call with veritas and emc.
===================
....
12:51:44.416 [3960.932] <2> read_data_ndmp: select returned 0. num_selects is 59
12:51:44.416 [3960.932] <2> mover_record_number: ready to call
ndmp_mover_get_state
12:51:44.416 [3960.932] <2> read_data_ndmp: record_num is 71107
12:53:41.933 [3960.932] <2> read_data_ndmp: notify_halted is 0,
notify_mover_halted is 0.
12:53:41.933 [3960.932] <2> read_data_ndmp: notify_halted is 0. doing another
select
12:54:11.933 [3960.932] <2> ndmp_check_time: sending keepalive to bpbrm
12:54:11.933 [3960.932] <2> read_data_ndmp: select returned 0. num_selects is 60
12:54:11.933 [3960.932] <2> mover_record_number: ready to call
ndmp_mover_get_state
12:54:11.933 [3960.932] <2> read_data_ndmp: record_num is 74015
12:55:56.981 [3960.932] <2> read_data_ndmp: notify_halted is 0,
notify_mover_halted is 0.
12:55:56.981 [3960.932] <2> read_data_ndmp: notify_halted is 0. doing another
select
12:56:26.982 [3960.932] <2> ndmp_check_time: sending keepalive to bpbrm
12:56:26.982 [3960.932] <2> read_data_ndmp: select returned 0. num_selects is 61
12:56:26.982 [3960.932] <2> mover_record_number: ready to call
ndmp_mover_get_state
12:56:26.982 [3960.932] <2> read_data_ndmp: record_num is 74442
12:59:01.468 [3960.932] <2> mover_halt_callback: mover halted--internal error
12:59:01.703 [3960.932] <2> set_job_details: Sending Tfile jobid (259658)
12:59:01.703 [3960.932] <2> set_job_details: LOG 1160045941 16 bptm 3960
NDMP_LOG_ERROR 0 Read failed on archive volume 1. No such file or directory .
12:59:01.703 [3960.932] <2> set_job_details: Done
12:59:01.703 [3960.932] <16> zacddat01: NDMP_LOG_ERROR 0 Read failed on archive
volume 1. No such file or directory .
12:59:01.703 [3960.932] <2> read_data_ndmp: notify_halted is 0,
notify_mover_halted is 3.
12:59:01.703 [3960.932] <2> read_data_ndmp: notify_halted is 0. doing another
select
12:59:02.562 [3960.932] <2> ndmp_check_time: sending keepalive to bpbrm
12:59:02.562 [3960.932] <2> read_data_ndmp: select returned 1. num_selects is 62
12:59:02.562 [3960.932] <4> zacddat01: NDMP_LOG_NORMAL 0 server_archive: emctar
vol 1, 121 files, 4802402304 bytes read, 0 bytes written
12:59:02.562 [3960.932] <2> read_data_ndmp: notify_halted is 0,
notify_mover_halted is 3.
12:59:02.562 [3960.932] <2> read_data_ndmp: notify_halted is 0. doing another
select
12:59:02.796 [3960.932] <2> read_data_ndmp: select returned 1. num_selects is 63
12:59:02.796 [3960.932] <2> read_data_ndmp: notify_halted is 4,
notify_mover_halted is 3.
12:59:02.796 [3960.932] <2> read_data_ndmp: restore done--notify_halted is 4
12:59:02.796 [3960.932] <2> read_data_ndmp: data stop status 0
12:59:02.796 [3960.932] <4> ndmp_wait_for_msg: notify_mover_halted already
arrived
12:59:02.796 [3960.932] <2> mover_record_number: ready to call
ndmp_mover_get_state
12:59:02.796 [3960.932] <2> read_data_ndmp: ndmp_mover_get_state:
ndmp_kbytes_read is 4689846
12:59:02.796 [3960.932] <2> ndmp_server_shutdown: data state =
NDMP_DATA_STATE_IDLE
12:59:02.796 [3960.932] <2> ndmp_server_shutdown: mover state =
NDMP_MOVER_STATE_HALTED
12:59:02.796 [3960.932] <2> ndmp_server_shutdown: ndmp_mover_stop status = 0
12:59:02.796 [3960.932] <2> read_data: read_data_ndmp returned -98
12:59:02.796 [3960.932] <2> set_job_details: Sending Tfile jobid (259658)
12:59:02.796 [3960.932] <2> set_job_details: LOG 1160045942 16 bptm 3960 cannot
restore from filepath /fs2, NDMP_HALT_INTERNAL_ERROR occurred
12:59:02.796 [3960.932] <2> set_job_details: Done
12:59:02.796 [3960.932] <16> read_data: cannot restore from filepath /fs2,
NDMP_HALT_INTERNAL_ERROR occurred
12:59:02.796 [3960.932] <2> nb_getsockconnected: host=zacdnbk01 service=bpcd
address=172.18.128.17 protocol=tcp reserved port=13782
12:59:02.796 [3960.932] <2> nb_bind_on_port_addr: bound to port 779
12:59:02.796 [3960.932] <2> nb_getsockconnected: Connect to zacdnbk01 on port
779
12:59:02.796 [3960.932] <2> logconnections: BPCD CONNECT FROM 172.18.128.17.779
TO 172.18.128.17.13782
12:59:02.796 [3960.932] <2> vauth_authentication_required: vauth_comm.c.781:
local address on reserved port: no authentication required
12:59:02.796 [3960.932] <2> vauth_connector: vauth_comm.c.181: local address on
reserved port: no authentication required
12:59:02.796 [3960.932] <2> bpcr_authenticate_connection: no authentication
required
12:59:02.796 [3960.932] <2> nb_bind_on_port_addr: bound to port 888
12:59:02.828 [3960.932] <2> read_data: Num_Kbytes_Read is 4689846
12:59:02.828 [3960.932] <2> signal_parent: set bpbrm media ready event (pid =
3788)
12:59:02.828 [3960.932] <2> io_ioctl: command (1)MTFSF 1 from (bptm.c.10930) on
drive index 2
....
============
Regards,
Claude Oliver
Veritas Support Engineer
email: coliver at faritec.com <mailto:coliver at faritec.com>
cell: 0832432956
work: 0118007608
DISCLAIMER:
This message may contain information which is confidential, private or
privileged in nature. If you are not the intended recipient, you may not
peruse, use, disseminate, distribute or copy this message or file which is
attached to this message. If you have received this message in error, please
notify the sender immediately by e-mail, facsimile or telephone and thereafter
return and/or destroy the original message.
Any views of this communication are those of the sender except where the sender
specifically states them to be those of Faritec (Holdings) Limited (Faritec)
and/or any of its subsidiaries including (but not limited to) Faritec
Enterprise Solutions (Proprietary) Limited, Faritec Strategic IT Services
(Proprietary) Limited, Faritec Contracting (Proprietary) Limited, Ebis and/or
any of its subsidiaries.
Please note that the recipient must scan this e-mail and any attached files for
viruses and the like. While we do everything possible to protect information
from viruses, Faritec accepts no liability of whatever nature for any loss,
liability, damage or expense resulting directly or indirectly from the access
and/or downloading of any files which are attached to this e-mail message.
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20061005/911e67b4/attachment.html
|