There are ways to see hardware on Sol9. Since you had to attach the library 
somehow then you most likely rebooted. If you did not issue a reconfigure 
reboot to rebuild your device tree. If you think you are okay then run, 
devfsadm -Cv to make sure. Then run some mt -f /dev/rmt/# status commands to 
see if you see the tape drives.
 
If that does not work take the server to the ok prompt, set auto-boot?= false, 
type reset-all and then run probe-scsi-all. It will poll the devices on the bus 
and report back. If that is good and you cannot see the drives or robot while 
in init 3 you need driver help. Call the library vendor or Sun for help.
 
Once you are confident you have the devices built run the scan command. The 
output is more useful (in my opinion). This will only work well if you have 
properly configged the sg/NBU devices within /kernel/drv/st.conf and 
/kernel/drv/sg.conf (AND taken a reboot. Not to mention the /etc/devlink.tab 
file.). That should be accomplished by running the 
/opt/openv/volmgr/bin/sg.build and /opt/openv/volmgr/bin/driver/sg.install 
scripts. See the /opt/openv/volmgr/MediaMgr_DeviceConfig_Guide.txt file for 
details. If you feel confident of your devices then you can use the scan output 
to configure drives and robots with the tpconfig utility. If you want a preview 
of what NBU sees run tpautoconf -r to look for robots and tpautoconf -t to look 
for tapes. If you feel brave run tpautoconf -a and it will config things up for 
you.
 
Good luck,
 
Bill

________________________________

From: veritas-bu-bounces at mailman.eng.auburn.edu on behalf of smpt
Sent: Wed 8/16/2006 11:10 PM
To: 'Nguyen, Patrick [LTD]'; veritas-bu at mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] Installing NetBackup 6.0



Run the command /usr/openv/volmgr/bin/sgscan 

If you see the L11000 in the hardware list then open the GUI (java or windows) 
and ran the hardware wizard.

If you don't see the library at the hardware level, call SUN to fix it. I think 
that the L11000 is a Quantum P3000 or P7000 library

 

smpt

 

________________________________

From: veritas-bu-bounces at mailman.eng.auburn.edu [mailto:veritas-bu-bounces 
at mailman.eng.auburn.edu] On Behalf Of Nguyen, Patrick [LTD]
Sent: Wednesday, August 16, 2006 10:42 PM
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] Installing NetBackup 6.0

 

Hi all,

I have a Sun Enterprise 420R with Solaris 9 and a Sun StorEdge L-11000. Since I 
am new with Veritas NetBackup 6.0, after I completed installing NetBackup 
Server and NetBackup Client, can someone tell me what do I need to install (on 
what CDs) and configure to make it recognize the L-11000? I have don't have 
support from Symantec because I have a temp license to evaluate.

Thanks in advanced

Patrick Nguyen
EMBARQ(tm) - Lnt-Natlnetops-Intelligenetsvc - Network Systems Admr II
Office: 407.741.0561  |  Wireless: 321.695.7219  |  Fax: 407-741-0455  |  
Email: patrick.p.nguyen at embarq.com
500 North New York Ave  -  Winter Park, Florida 32789  -  Mailstop: FLWNTC0103 
- 1018

This message (including any attachments) may contain privileged material, 
non-public information or proprietary information and is for the intended 
recipients only. If you are not the intended recipient, you should notify the 
sender and delete this message. Any disclosure, copying, or use of this 
information is strictly prohibited and may subject you to legal liability

-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20060816/f34dc838/attachment.html

<Prev in Thread] Current Thread [Next in Thread>