Veritas-bu

[Veritas-bu] Master Server Migration Question

2006-08-16 01:28:53
Subject: [Veritas-bu] Master Server Migration Question
From: smpt at peppas.gr (smpt)
Date: Wed, 16 Aug 2006 08:28:53 +0300
As far as I know UNIX and windows NetBackup databases are not compatible. I
haven't tried but the problem must be at the carriage return of the image
files. It is something that you need a script to overcome.

smpt

 

 

  _____  

From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Steven L.
Sesar
Sent: Monday, August 14, 2006 4:43 AM
To: Katauskas, Daryl
Cc: veritas-bu at mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] Master Server Migration Question

 

I did this a few years ago - cooked a Windows and two Solaris masters down
onto one Solaris master. It was non-trivial, there were several file
conversions, definitely not for the faint of heart. Have your Perl/Shell
scripting skills handy, because you will need them. Let me see if I can dig
up my notes. They may be of some help. Caveat: I did this under 4.5. 

--Steve

Katauskas, Daryl wrote: 

 

Hello Everybody:

I have a quck question regarding NBU Master server migration. We are
currently in the process of beginning to plan a migration of our Solaris 9
v5.1 Master/Media server to a v5.1 Windows platform.

We are planning on doing the following:

1. Build Windows NBU Master/Media Server with the same name as the exisitng
Solaris Master Media.

2. Perform a catalog backup of the existing Solaris Master/Media server.

3. Move existing library to new master/Media server.

4. Perform a catalog recovery on the new Windows Master/Media server using
the catalog backup performed from the original Solaris Master.

Does anyone know if this will work or if there are any file conversion
needed when restoring the catalog created on a Solaris Master to a Windows
Master of the same name?

Any feedback would be appreciated.

Regards,

Daryl Katauskas

 





  _____  



 
_______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
  






-- 
===================================
 
   Steven L. Sesar
   Lead Operating Systems Programmer/Analyst
   UNIX Application Services R101
   The MITRE Corporation
   202 Burlington Road - MS K101
   Bedford, MA 01730
   tel: (781) 271-7702
   fax: (781) 271-2600
   mobile: (617) 519-8933
   email: ssesar at mitre.org
 
=================================== 