Bank of America, hunh?
Bunch of friends of mine work at your new Canadian office in Ottawa.
(formerly MBNA)
 
Anyhow, with my GF940s, I connected the tape drives to the filer,
installed the NDMP pack on the master, created some policies and started
ripping data off at about 30+ MB/s
 
the data rates you're seeing in Netbackup aren't necessarily accurate,
as the NAS spends a lot of time preparing data for the backup, so that
time with no data transfer is counted in the data/time factoring, as far
as I can tell.
you'd be better off monitoring your throughput at a switchport of
similar.
 
I get sub 1MB/s rates backing up 2 TB in about 45 minutes, but the first
30 minutes is scanning the filesystem, preparing the dump image, and
sending the index/catalog info to the backup server.
 
make sure you've got good pipe from filer -> master.
NDMP is a chatty protocol and does require a decent IP pipe to talk to
the master....
 
Paul
 
 
-- 

        -----Original Message-----
        From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Clooney,
David
        Sent: July 19, 2006 8:56 AM
        To: veritas-bu at mailman.eng.auburn.edu
        Subject: [Veritas-bu] NDMP Performance
        
        
        
        Hi all
         
        Just a quick Q for guidance really . I'm trying to investigate
on ways to increase throughput on NDMP backups 
         
             NetApp R200
             Storagetek L700
             STK 9940b 
         
        Currently averaging around  5mb/sec , surely this can be
improved ?
         
        Any starting points would be grateful.
         
        Dave Clooney

-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20060719/4719d3f2/attachment.html
-------------- next part --------------
====================================================================================

La version fran?aise suit le texte anglais.

------------------------------------------------------------------------------------

This email may contain privileged and/or confidential information, and the Bank 
of
Canada does not waive any related rights. Any distribution, use, or copying of 
this
email or the information it contains by other than the intended recipient is
unauthorized. If you received this email in error please delete it immediately 
from
your system and notify the sender promptly by email that you have done so. 

------------------------------------------------------------------------------------

Le pr?sent courriel peut contenir de l'information privil?gi?e ou 
confidentielle.
La Banque du Canada ne renonce pas aux droits qui s'y rapportent. Toute 
diffusion,
utilisation ou copie de ce courriel ou des renseignements qu'il contient par une
personne autre que le ou les destinataires d?sign?s est interdite Si vous 
recevez
ce courriel par erreur, veuillez le supprimer imm?diatement et envoyer sans 
d?lai ?
l'exp?diteur un message ?lectronique pour l'aviser que vous avez ?limin? de 
votre
ordinateur toute copie du courriel re?u.

<Prev in Thread] Current Thread [Next in Thread>