Veritas-bu

[Veritas-bu] Moving media from one master to another.

2006-07-17 08:37:00
Subject: [Veritas-bu] Moving media from one master to another.
From: Jonathan.Dyck at cognos.com (Dyck, Jonathan)
Date: Mon, 17 Jul 2006 08:37:00 -0400
It's definitely possible, although it tends to be one of those things
Veritas likes to hold in their back pocket for PS work (i.e: you
probably won't find good documentation around on how to do it).

I've recently had an NBU 5.1 MP4 catalog migrated from a Sol. 9 master
to a new Windows master (which made it a little easier, as volume pools
could be duplicated on the new master getting rid of the problem with
the old volume pool id's).  I also had a quote to merge my two masters
into a single at one point...

Cheers,
Jon

-----Original Message-----
From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of WEAVER,
Simon
Sent: Monday, July 17, 2006 2:21 AM
To: 'Jim Horalek'; Veritas-Bu
Subject: Re: [Veritas-bu] Moving media from one master to another.


Jim
Not sure this is actually possible, because both masters would not be
sharing the same Database, therefore would not know anything about the
media id (that's my understanding).

I would assume that the only possible cause of action is to import the
tape or tapes into the master which will then populate its own internal
database.

Guys, help me out if I am wrong here

Regards

Simon Weaver
3rd Line Technical Support
Windows Domain Administrator 

EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU

Email: Simon.Weaver at Astrium-eads.net



-----Original Message-----
From: Jim Horalek [mailto:jimh at federaledge.com]
Sent: 13 July 2006 20:44
To: Veritas-Bu
Subject: [Veritas-bu] Moving media from one master to another.


Anyone know how to move media from on mastet to another master? Cavat
old
server is an Sgi(Unix) New server is Windows.
Note: I'm not trying to keep the same hostname for the master. Bpmedia
??
NBU 5.0

Thanks.

Jim

_______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email is for the intended addressee only.
If you have received it in error then you must not use, retain,
disseminate or otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or
obligation.

EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
_______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
 
     This message may contain privileged and/or confidential information.  If 
you have received this e-mail in error or are not the intended recipient, you 
may not use, copy, disseminate or distribute it; do not open any attachments, 
delete it immediately from your system and notify the sender promptly by e-mail 
that you have done so.  Thank you.