Veritas-bu

[Veritas-bu] RE: Veritas-bu digest, Vol 1 #5075 - 7 msgs

2006-04-11 08:16:49
Subject: [Veritas-bu] RE: Veritas-bu digest, Vol 1 #5075 - 7 msgs
From: L.Veldhuizen AT agisweb DOT nl (Veldhuizen, Louis)
Date: Tue, 11 Apr 2006 14:16:49 +0200
Hi Yoseph,

You also need to tell the database you want to move the tape to another
mediaserver. I think this is done with the bpmedia command.
Hope this helps.

Louis

Date: Tue, 11 Apr 2006 02:10:10 -0700 (PDT)
From: Yoseph Leleputra <leleputra AT yahoo DOT com>
To: Veritas Expert <veritas-bu AT mailman.eng.auburn DOT edu>
Subject: [Veritas-bu] Restore at different storage Unit

--0-1821636614-1144746610=:96433
Content-Type: text/plain; charset=iso-8859-1
Content-Transfer-Encoding: 8bit

Hi Gurus, 
  I have a challenge from my boss to restore data between 2 storage
unit. 
  My environement, I have 1 master server ( using solaris 8 ) and 1
media server ( windows 2000 ) server. 
  Master Server connect with IBM Anaconda using 6 LTO-1 tape drives
  Media server have ADIC I2K using 4 LTO-2 tape drives. 
  My challence is can I restore my data from backup at IBM Anaconda, and
restore it with ADIC I2K 
  Today I try to do it but , when I run inventory robot at media server
I got this messagge below.
  Maybe some one who experience with this situation, could share to me 
  Thanks 
  Yoseph 
  
   
  04/11/2006 15:21:29
  Robot: TLD(1) on jafs22
  Operation: Preview of Inventory and Update
  Volume Database Host: jatce01
  --------------------------------------------------------------------
  Generating list of recommended changes ...
  Proposed Change(s) to Update the Volume Configuration
  =====================================================
  Logically add new media 549WMO (barcode 549WMO) to robot slot 7.
  Logically add new media 708WMO (barcode 708WMO) to robot slot 5.
  Logically add new media 650WMO (barcode 650WMO) to robot slot 6.
  --------------------------------------------------------------------
  Updating volume configuration ...
  Processing new media added to the robotic library by logically
  adding media with new media IDs as follows...
  Media ID Slot
  ======== ====
  Update failed: could not add new media ID '549WMO' into slot 7
  Insert media failed:
  media ID not unique in database (34)

**********************************************************************
Dit e-mailbericht is vertrouwelijk en uitsluitend bestemd voor de 
geadresseerde. Gebruik van deze informatie door anderen dan de geadresseerde is 
niet toegestaan.

Als u dit bericht foutief hebt ontvangen, wordt u vriendelijk verzocht dit aan 
de afzender te melden. Agis Zorgverzekeringen staat door de elektronische 
verzending van dit bericht niet in voor de juiste en volledige overbrenging van 
de inhoud, noch voor tijdige ontvangst daarvan. Agis Zorgverzekeringen 
controleert alle uitgaande e-mail op computervirussen.
**********************************************************************


<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] RE: Veritas-bu digest, Vol 1 #5075 - 7 msgs, Veldhuizen, Louis <=