Not here - In fact I stand by my previous response - in that you can
configure a LTO2 Drive to accept an LTO1 drive.

Must admit, not seen the problem you mention with regards to
data_buffer_size, although maybe it can cause problems with recovering data
on old tapes

Simon Weaver 
Technical Support 
Windows Domain Administrator 

EADS Astrium 
Tel: 02392-708598 

Email: Simon.Weaver AT Astrium.eads DOT net 



-----Original Message-----
From: Viv [mailto:viv AT bassani DOT info] 
Sent: 22 March 2006 21:06
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Re Veritas-bu] LTO 1 recovery using LTO 2 drive.


Thanks for the replies on this.

We have since found that the DATA_BUFFERS_SIZE on some of the media servers
could be causing this issue. For some reason (may be to do with
performance) they have been set to 4MB. Has anyone else experienced problems
with such high block sizes?

thanks

__________________________________________________________________________



Hmmm...

Likely that the underlying device is issuing some sort of message that
NetBackup doesn't like. Which FP/MP of 4.5? What is the OS of the media
server?

Check the underlying OS message file on the media server for clues.

Speculation: There may be an issue with the LTO driver you're using not
automatically reading the LTO1 tapes as it should. Whenever possible, the
latest stable driver for the tape and the OS of the media server should be
used. This sort of sounds like issues with an LTO driver or a generic scsi
tape driver.

Mickey Baker
Fort Lauderdale, FL

-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of
viv AT bassani DOT info
Sent: Tuesday, March 14, 2006 1:56 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] LTO 1 recovery using LTO 2 drive.

We are currently backing up a system with LTO gen 1 drives/media and trying
to recover using LTO gen 2 drives (LTO 1 drives are IBM and LTO 2 drives are
HP). We are using NBU 4.5 and when the LTO 1 tapes are loaded into the gen 2
drive, the drives are downed. Any ideas what can be causing this is
appreciated.

--
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu





----------------------------------------------------------------------------
----


Previous message: [Veritas-bu] LTO 1 recovery using LTO 2 drive. Next
message: [Veritas-bu] determining drive that a backup used Messages sorted

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email is for the intended addressee only.
If you have received it in error then you must not use, retain, disseminate or 
otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS 
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or 
obligation.

EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England

<Prev in Thread] Current Thread [Next in Thread>