Veritas-bu

[Veritas-bu] RMAN - Oracle Backup issue

2006-03-06 11:33:01
Subject: [Veritas-bu] RMAN - Oracle Backup issue
From: JMARTI05 AT intersil DOT com (Martin, Jonathan (Contractor))
Date: Mon, 6 Mar 2006 11:33:01 -0500
All,

I've recently been having issues with a large Oracle DB Backup (2TB.)
Because of the application criticality we can only run this during the
weekend, and its failed several weekends in a row.  Basically the errors
I am getting in Netbackup vary from 84 Media Write Errors to Errors 6 &
54 - Unable to Communicate with Client.  The media however if used in
another backup is not bad, and I've tired now for several weeks using
different tape drives.  I'm thinking this is some sort of an RMAN /
Netbackup communication issue.

The RMAN log always looks like this...

RMAN-10035: exception raised in RPC: ORA-19502: write error on file
"MDS1_bk_22057_1_584295994", blockno 183521025 (blocksize=512)
ORA-27030: skgfwrt: sbtwrite2 returned error
ORA-19511: VxBSASendData: Failed with error:
   Server Status:  Communication with the server has not been iniatated
or the server status has not been retrieved from the server.
RMAN-10031: ORA-19624 occurred during call to
DBMS_BACKUP_RESTORE.BACKUPPIECECREATE

But NBU is reporting Media Errors and Client Communications issues.

Any ideas?

-Jonathan



-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of Bob Stump
Sent: Monday, March 06, 2006 9:52 AM
To: Simon WEAVER; 'dave.markham AT fjserv DOT net'
Cc: 'veritas-bu AT mailman.eng.auburn DOT edu'
Subject: RE: [Veritas-bu] should you move live media to a new pool -
thoughtit woudl fail

Well, it can be de-assigned and reassigned.
but you may get problems with error code 94's

How to do it? Check out the how to fix error code 94's

Media Manager error 94: "Volume not in specified pool" - scenarios and
solutions http://seer.support.veritas.com/docs/247898.htm 


personally, I would just do a bpduplicate and make the duplicate the
primary copy and then expire copy 1.




>>> "WEAVER, Simon" <simon.weaver AT astrium.eads DOT net> 3/6/2006 8:59:54 AM
>>>

Dave
That is EXACTLY what I told them!! (people who know better!!)

Sure this was the case, but my understanding is this:

1) When a Media ID (or volume if you want to call it that) is assigned
to a
Volume Pool, its stuck there
2) The Volume will STAY here until its expired or manually expired or
deassigned
3) There are valid images on the media - trying to deassign could lose
them
(or cause issues)
4) Should plan better when using Volume Poole

Any comments welcome

Simon Weaver 
Technical Support 
Windows Domain Administrator 

EADS Astrium 
Tel: 02392-708598 

Email: Simon.Weaver AT Astrium.eads DOT net 



-----Original Message-----
From: Dave Markham [mailto:dave.markham AT fjserv DOT net] 
Sent: 06 March 2006 13:56
To: WEAVER, Simon
Cc: 'veritas-bu AT mailman.eng.auburn DOT edu'
Subject: Re: [Veritas-bu] should you move live media to a new pool -
thoughtit woudl fail


I don't think you can change volume pools of a tape if it has images on
it.
It normally needs to be expired first, which of course will mean it can
be
re-used.

Dave

WEAVER, Simon wrote:
> Hi
> Could I get clarification? If I ran a Month end backup with a 1 year 
> retention, but it accidently directed into a wrong volume pool, am I 
> right in saying it cannot be moved?
>  
> I thought if you deassigned a media ID from a volume, Netbackup would 
> forget about it and treat it as a new tape?? Clarification please if 
> you could :-) Thanks
>  
>
> *Simon Weaver*
> *Technical Support*
> *Windows Domain Administrator*
>
> */EADS Astrium/*
> */Tel: 02392-708598/*
>
> *Email: Simon.Weaver AT Astrium.eads DOT net* 
>
>  
> This email is for the intended addressee only.
> If you have received it in error then you must not use, retain, 
> disseminate or otherwise deal with it. Please notify the sender by 
> return email. The views of the author may not necessarily constitute 
> the views of EADS Astrium Limited.
> Nothing in this email shall bind EADS Astrium Limited in any contract
> or obligation.
>
> EADS Astrium Limited, Registered in England and Wales No. 2449259 
> Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 
> 2AS, England
>

This email is for the intended addressee only.
If you have received it in error then you must not use, retain,
disseminate or otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or
obligation.

EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu 
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] RMAN - Oracle Backup issue, Martin, Jonathan (Contractor) <=