I am using an L700 tape library.
=20
5- STK9840 drives
4- HPUltrium2-SCSI Drives
=20
All drives connect via fiber.
The host is a SunOS 5.8 box running Veritas NetBackup 5.1.
There is something going on with the Fiber+I/O Port Configuration.
Basically a couple weeks ago the first four STK9840 tape drives went
down (in veritas: DOWN/TLD) when Veritas tries to write to these tape
drives.
We get "I/O port error cannot open port."
=20
I thought it was an issue with the drives.
=20
I changed the fiber loop for the A/B addresses for the four STK9840
drives to 02/02, 03/03, 04/04, 05/05.
After I did this, four of the drives came up successfully but then four
other drives went down.
=20
Does anyone know the key to setting the fiber addresses?
=20
The panel says:
=20
1-125 for HARD PORT (this is what I am using)
126 for SOFT PORT (this disables the port)
=20
Are there any StorageTek technicians or users of the L700 who may have
had similar problems in the past?
=20
Thanks!
=20
Justin.
=20
=20
=20
------_=_NextPart_001_01C55B0A.CD59A232
Content-Type: text/html;
charset="us-ascii"
Content-Transfer-Encoding: quoted-printable
<html xmlns:o=3D"urn:schemas-microsoft-com:office:office" =
xmlns:w=3D"urn:schemas-microsoft-com:office:word" =
xmlns:st1=3D"urn:schemas-microsoft-com:office:smarttags" =
xmlns=3D"http://www.w3.org/TR/REC-html40">
<head>
<META HTTP-EQUIV=3D"Content-Type" CONTENT=3D"text/html; =
charset=3Dus-ascii">
<meta name=3DGenerator content=3D"Microsoft Word 11 (filtered medium)">
<o:SmartTagType =
namespaceuri=3D"urn:schemas-microsoft-com:office:smarttags"
name=3D"PlaceType"/>
<o:SmartTagType =
namespaceuri=3D"urn:schemas-microsoft-com:office:smarttags"
name=3D"PlaceName"/>
<o:SmartTagType =
namespaceuri=3D"urn:schemas-microsoft-com:office:smarttags"
name=3D"place"/>
<!--[if !mso]>
<style>
st1\:*{behavior:url(#default#ieooui) }
</style>
<![endif]-->
<style>
<!--
/* Style Definitions */
p.MsoNormal, li.MsoNormal, div.MsoNormal
{margin:0in;
margin-bottom:.0001pt;
font-size:12.0pt;
font-family:"Times New Roman";}
a:link, span.MsoHyperlink
{color:blue;
text-decoration:underline;}
a:visited, span.MsoHyperlinkFollowed
{color:purple;
text-decoration:underline;}
span.EmailStyle17
{mso-style-type:personal-compose;
font-family:Arial;
color:windowtext;}
@page Section1
{size:8.5in 11.0in;
margin:1.0in 1.25in 1.0in 1.25in;}
div.Section1
{page:Section1;}
-->
</style>
</head>
<body lang=3DEN-US link=3Dblue vlink=3Dpurple>
<div class=3DSection1>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>I am using an L700 tape =
library.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>5- STK9840 drives<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>4- HPUltrium2-SCSI =
Drives<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>All drives connect via =
fiber.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>The host is a SunOS 5.8 box running Veritas NetBackup =
5.1.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>There is something going on with the Fiber+I/O Port
Configuration.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>Basically a couple weeks ago the first four STK9840 =
tape
drives went down (in veritas: DOWN/TLD) when Veritas tries to write to =
these
tape drives.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>We get “I/O port error cannot open =
port.”<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>I thought it was an issue with the =
drives.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>I changed the fiber loop for the A/B addresses for =
the four
STK9840 drives to 02/02, 03/03, 04/04, =
05/05.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>After I did this, four of the drives came up =
successfully
but then four other drives went down.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>Does anyone know the key to setting the fiber =
addresses?<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>The panel says:<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>1-125 for HARD PORT (this is what I am using)<br>
126 for <st1:place w:st=3D"on"><st1:PlaceName =
w:st=3D"on">SOFT</st1:PlaceName> <st1:PlaceType
w:st=3D"on">PORT</st1:PlaceType></st1:place> (this disables the =
port)<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>Are there any StorageTek technicians or users of the =
L700
who may have had similar problems in the =
past?<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>Thanks!<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'>Justin.<o:p></o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
<p class=3DMsoNormal><font size=3D2 face=3DArial><span =
style=3D'font-size:10.0pt;
font-family:Arial'><o:p> </o:p></span></font></p>
</div>
</body>
</html>
------_=_NextPart_001_01C55B0A.CD59A232--
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- [Veritas-bu] L700 StorageTek Question w/Veritas,
Piszcz, Justin <=
|
|
|