Veritas-bu

[Veritas-bu] Error 84 - ???

2004-09-15 11:39:01
Subject: [Veritas-bu] Error 84 - ???
From: dlogcher AT MIT DOT EDU (Dan Logcher)
Date: Wed, 15 Sep 2004 11:39:01 -0400
Indeed.  I have caused this to backups by doing a file on the
tape device during a backup.  Opps.

--
Dan

Tal Shekel wrote:

> Check if there is any 3rd party software monitoring your tape devices.
> 
> I have had a few cases where disabling the fibre and scsi agents of 
> insight manager resolved issues like this.
> 
>  
> 
>  
> 
> -----Original Message-----
> From: Johan Redelinghuys [mailto:johan.redelinghuys AT stg.co DOT za]
> Sent: 15 September 2004 08:50 AM
> To: veritas-bu AT mailman.eng.auburn DOT edu
> Subject: [Veritas-bu] Error 84 - ???
> 
>  
> 
>  
> 
> Hi
> 
>  
> 
> One of our customers is having a lot of error 84 backup problems. We 
> replaced drives, firmware, switches etc. What else can we look at, that 
> had solved the problem for you?
> 
>  
> 
> JR



<Prev in Thread] Current Thread [Next in Thread>