[Veritas-bu] Error 84 - ???
2004-09-15 11:39:01
Subject: |
[Veritas-bu] Error 84 - ??? |
From: |
dlogcher AT MIT DOT EDU (Dan Logcher) |
Date: |
Wed, 15 Sep 2004 11:39:01 -0400 |
Indeed. I have caused this to backups by doing a file on the
tape device during a backup. Opps.
--
Dan
Tal Shekel wrote:
> Check if there is any 3rd party software monitoring your tape devices.
>
> I have had a few cases where disabling the fibre and scsi agents of
> insight manager resolved issues like this.
>
>
>
>
>
> -----Original Message-----
> From: Johan Redelinghuys [mailto:johan.redelinghuys AT stg.co DOT za]
> Sent: 15 September 2004 08:50 AM
> To: veritas-bu AT mailman.eng.auburn DOT edu
> Subject: [Veritas-bu] Error 84 - ???
>
>
>
>
>
> Hi
>
>
>
> One of our customers is having a lot of error 84 backup problems. We
> replaced drives, firmware, switches etc. What else can we look at, that
> had solved the problem for you?
>
>
>
> JR
|
|
|