Veritas-bu

[Veritas-bu] my hp storageworks 1/8 can't be configured correctly with Netbackup 4.5

2004-09-02 20:17:04
Subject: [Veritas-bu] my hp storageworks 1/8 can't be configured correctly with Netbackup 4.5
From: moliver AT lgi DOT com (Miles D. Oliver)
Date: Thu, 2 Sep 2004 20:17:04 -0400 (EDT)
On Thu, 2 Sep 2004, Marianne van den Berg wrote:

 Baby Steps.....

 I've got the drive up now and have successfully executed a manual backup.

 Now to get review the policies and schedules and get them in order and
then on to tackle the ORACLE and RMAN part of this process.

 The whole process is a bit more work from the command line but it is
coming.

 Thanks for all the help.


> Hi
>
> The 213 error is because your drive is DOWN.
>
> To find out why your drive is down, you need a VERBOSE entry in 
> /usr/openv/volmgr/vm.conf. Stop/start ltid, 'UP' the drive, try to backup. If 
> the drive is 'downed' again, you will find the reason in /var/adm/messages.
>
>
> Let my share my experience as far as SCSI connected devices are concerned:
> I have found that drives get 'downed' with nothing really wrong when the SCSI 
> target of the robot is higher that that of the drives, especially when they 
> are daisy-chained on the same bus.
>
> I could get robtest to work, but backups would fail.
>
> Try to change scsi targets around:
> Drive - target 5
> Robot - target 4.
>
> You will have to re-config O/S device names and update NetBackup.
>
> Regards
>
> Marianne van den Berg
> Veritas Professional Services
> LECHABILE Storage Solutions (PTY) Ltd
> Tel: +27 11 519 8134
> Mobile: +27 82 468 8107
> Fax: +27 11 519 8147
> mailto: mariannev AT lechabiless.co DOT za
>
> This e-mail and attachments relating thereto, is intended for the 
> above-mentioned recipient. If you have received this e-mail in error, kindly 
> notify the sender and delete it immediately as it contains information 
> relating to the official business of Lechabile Storage Solutions (Pty) 
> Limited, which is confidential, legally privileged and proprietary to 
> Lechabile Storage Solutions (Pty) Limited. Lechabile Storage Solutions (Pty) 
> Limited does not own and endorse any other content. The views and opinions 
> expressed in this e-mail are those of the sender unless clearly stated as 
> being those of Lechabile Storage Solutions (Pty) Limited.
>
>
>
> -----Original Message-----
> From: Miles D. Oliver [mailto:moliver AT lgi DOT com]
> Sent: Thursday, September 02, 2004 3:22 AM
> To: veritas-bu AT mailman.eng.auburn DOT edu
> Subject: [Veritas-bu] my hp storageworks 1/8 can't be configured
> correctly with Netbackup 4.5
>
>
>
>  I've got a messed up netbackup configuration and can't seem to even
> address the tape library properly.  I'm a newbie, trying to understand but
> I'm overwhelmed. I've been searching and searching the archives and have
> been able to find some info but I can't be sure if I'm on the right track.
>
>  1. I've got to do this all from the command line. I don't have access to
> the GUI as I'm doing this remotely.
>
>  2. For every backup I try to execute, either scheduled or manual, I get a
> "no storage units available for use (213)" error.
>
>  bpperror lists.
>
>  1094084620 1 4 4 oradev 0 0 0 *NULL* bpsched cleaning job DB
> 1094084621 1 4 16 oradev 0 0 0 *NULL* bpsched scheduler exiting - no
> storage units available for use (213)
> 1094085220 1 4 4 oradev 0 0 0 *NULL* bpsched cleaning job DB
> 1094085221 1 4 16 oradev 0 0 0 *NULL* bpsched scheduler exiting - no
> storage units available for use (213)
> 1094085820 1 4 4 oradev 0 0 0 *NULL* bpsched cleaning job DB
> 1094085821 1 4 16 oradev 0 0 0 *NULL* bpsched scheduler exiting - no
> storage units available for use (213)
> 1094086421 1 4 4 oradev 0 0 0 *NULL* bpsched cleaning job DB
> 1094086421 1 4 16 oradev 0 0 0 *NULL* bpsched scheduler exiting - no
> storage units available for use (213)
>
>  2.  output from tpautoconf -show is different from tpconfig -dl
>
>  oradev# tpautoconf -show
>
> HP      ThinStor AutoLdrH33r /dev/sg/c1t5l0
>    Drive 1:    - Not locally connected or robot not serialized.
>
> Standalone or unserialized drives, or robot not locally connected:
> oradev# tpconfig -dl
> Currently defined drives and robots are:
>
>         Drive Name              HPUltrium1-SCSI0
>         Index                   0
>         NonRewindDrivePath      /dev/rmt/0cbn
>         Type                    hcart
>         Status                  DOWN
>         Shared Access           No
>         TLD(0) Definition       DRIVE=1
>
> Currently defined robotics are:
>   TLD(0)     robotic path = /dev/sg/c1t5l0,
>              volume database host = oradev
>
>  sgscan shows
>
> oradev# sgscan -v
> /dev/sg/c0t0l0: Disk (/dev/rdsk/c0t0d0): "FUJITSU MAP3367NC       0106"
> /dev/sg/c0t1l0: Disk (/dev/rdsk/c0t1d0): "FUJITSU MAP3367NC       0106"
> /dev/sg/c0t6l0: Cdrom: "TEAC    CD-ROM CD-532S  1.0A"
> /dev/sg/c1t4l0: Tape (/dev/rmt/0): "HP      Ultrium 1-SCSI  E00P"
> /dev/sg/c1t5l0: Changer: "HP      ThinStor AutoLdrH33r"
>
>
>  robtest allows me to contact the tape library and move tapes so I know
> that I am contacting the library but I just can't seem to get netbackup to
> see it and use it.
>
>  How can I get my tape library configuration straight so that I can start
> accessing it properly??
>
>  Thanks for the help, I'm at my wits end,
>
>  Miles D. Oliver
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>


 Miles D. Oliver
 Senior Systems Engineer
 The Legnem Group Inc. - LGI
 5501 Twin Knolls Road
 Suite 107
 Columbia, Maryland 21045
 VOICE  410-997-1393
 FAX    410-720-1241
 EMAIL  miles.oliver AT lgi DOT com
 WEB    www.lgi.com