Veritas-bu

[Veritas-bu] socket read failed

2004-08-31 11:51:58
Subject: [Veritas-bu] socket read failed
From: dlogcher AT MIT DOT EDU (Dan Logcher)
Date: Tue, 31 Aug 2004 11:51:58 -0400
Dan Logcher wrote:

> We recently upgraded our Master and Media servers from Tru64 5.1A
> 
> to 5.1B in both datacenters.  Development Datacenter is working fine,
> but Production master server is giving me socket read failed when I
> try to run bpmedialist.  I can run it in DEV.
> 
> I tried rebooting the master, but to no avail.  Any thoughts on
> what this is?  We applied the inetd.mod patch that HP recommended
> when we did Development servers.  This is a new problem.

An added note..  I can run bpmedialist -h media_server and it works.

-- 
Dan