[Veritas-bu] Library based cleaning [L180]

2004-08-18 13:52:40
Subject: [Veritas-bu] Library based cleaning [L180]
From: joe AT joe DOT net (Johnny Oestergaard)
Date: Wed, 18 Aug 2004 19:52:40 +0200
Our L180 is almost 4 years old now and we have never used anything else 
then the library based cleaning.

We had a small problem in the beginning, but that was because we didn't put 
the cleaningtapes in the service slots in the library.
But we use 9940B's, and before that 9940A's.

But I remember that I read something somewhere that the problem is the LTO 
drives. Origialy there was nothing about tapecleaning in the LOT specs so 
the drives don't signal to the library that they need cleaning.
I also think that only two of the 3 major LTO vendors have implemented 
signaling of cleaning, but I don't remember who it was (but I think IBM was 
one of them), but only on LTO1 and not LTO2.

But since we don't use LTO I don't follow that kind of info so closely.

/johnny




At 11:05 18-08-2004 -0600, King, Cheryl wrote:
>We have an STK L180 and could not get the library based cleaning to work 
>automatically.  STK claims it works but it never did.  I tried the 
>/usr/openv/volmgr/database/NO_TAPEALERT, it didn't seem to work.  I ended 
>up using Tape alert.  It works great except if your tape drives go bad and 
>starts using up all the cleanings.  Nothing is perfect.
>
>-----Original Message-----
>From: veritas-bu-admin AT mailman.eng.auburn DOT edu
>[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of
>jamesp AT hisser DOT org
>Sent: Wednesday, August 18, 2004 9:27 AM
>To: Smith, Kevin
>Cc: veritas-bu AT mailman.eng.auburn DOT edu
>Subject: Re: [Veritas-bu] Library based cleaning [L180]
>
>
>The drives are raising a TapeAlert as they want cleaning, but no cleaning 
>tapes
>are available in NetBackup - as you are doing library based cleaning.
>
>Either configure the library to NOT send TapeAlerts, or use the following
>touchfile (UNIX) to disable this functionality:
>
>/usr/openv/volmgr/database/NO_TAPEALERT
>
>Cheers
>
>James
>
>Quoting "Smith, Kevin" <kevin.m.smith AT siemens DOT com>:
>
> > All,
> >
> > I have a Sun badged L180 which has 5 new cleaning tapes inserted in 
> with LTO
> > type cleaning labels. Therefore I am using library based cleaning and
> > control of this is removed from netbackup. Every four hours I get a message
> > from ltid saying that "there is no cleaning tape or the cleaning tape has
> > expired". I have RTFM the L180 OPS guide ETC but I guess the situation lies
> > within netbackup - can anyone shed some light on this.
> >
> > TIA
> >
> > Kev.
> >
> >       ---------------------------------------------------
> >       Kev Smith
> >       Unix Systems Administrator.
> >       Operational Support, IND Croydon.
> >
> >       E-Mail: kevin.m.smith AT siemens.com
> >       Tel:    020 8760 3358
> >       Mob:    07808 828595
> >       ---------------------------------------------------
> >
> >       This e-mail contains confidential information and is for the
> > exclusive use of the addressee/s. If you are not the addressee, then any
> > distribution, copying or use of this e-mail is prohibited. If received in
> > error, please advise the sender and delete it immediately. We accept no
> > liability for any loss or damage suffered by any person arising from use of
> > this e-mail.
> >
> > Siemens Business Services Limited
> > Registered No: 1203466 England
> > Registered Office: Siemens House, Olbury, Bracknell,  Berkshire, RG12 8FZ
> >
> >
> >
>
>
>
>_______________________________________________
>Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
>http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>