Veritas-bu

[Veritas-bu] Library based cleaning [L180]

2004-08-18 13:05:23
Subject: [Veritas-bu] Library based cleaning [L180]
From: cheryl.king AT intrado DOT com (King, Cheryl)
Date: Wed, 18 Aug 2004 11:05:23 -0600
We have an STK L180 and could not get the library based cleaning to work 
automatically.  STK claims it works but it never did.  I tried the 
/usr/openv/volmgr/database/NO_TAPEALERT, it didn't seem to work.  I ended up 
using Tape alert.  It works great except if your tape drives go bad and starts 
using up all the cleanings.  Nothing is perfect.

-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of
jamesp AT hisser DOT org
Sent: Wednesday, August 18, 2004 9:27 AM
To: Smith, Kevin
Cc: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Library based cleaning [L180]


The drives are raising a TapeAlert as they want cleaning, but no cleaning tapes
are available in NetBackup - as you are doing library based cleaning.

Either configure the library to NOT send TapeAlerts, or use the following
touchfile (UNIX) to disable this functionality:

/usr/openv/volmgr/database/NO_TAPEALERT

Cheers

James

Quoting "Smith, Kevin" <kevin.m.smith AT siemens DOT com>:

> All,
>
> I have a Sun badged L180 which has 5 new cleaning tapes inserted in with LTO
> type cleaning labels. Therefore I am using library based cleaning and
> control of this is removed from netbackup. Every four hours I get a message
> from ltid saying that "there is no cleaning tape or the cleaning tape has
> expired". I have RTFM the L180 OPS guide ETC but I guess the situation lies
> within netbackup - can anyone shed some light on this.
>
> TIA
>
> Kev.
>
>       ---------------------------------------------------
>       Kev Smith
>       Unix Systems Administrator.
>       Operational Support, IND Croydon.
>
>       E-Mail: kevin.m.smith AT siemens.com
>       Tel:    020 8760 3358
>       Mob:    07808 828595
>       ---------------------------------------------------
>
>       This e-mail contains confidential information and is for the
> exclusive use of the addressee/s. If you are not the addressee, then any
> distribution, copying or use of this e-mail is prohibited. If received in
> error, please advise the sender and delete it immediately. We accept no
> liability for any loss or damage suffered by any person arising from use of
> this e-mail.
>
> Siemens Business Services Limited
> Registered No: 1203466 England
> Registered Office: Siemens House, Olbury, Bracknell,  Berkshire, RG12 8FZ
>
>
>



_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


<Prev in Thread] Current Thread [Next in Thread>