Veritas-bu

[Veritas-bu] Tape ID cannot detect it on netbackup 5.0 (win2003)

2004-08-18 11:53:58
Subject: [Veritas-bu] Tape ID cannot detect it on netbackup 5.0 (win2003)
From: jamesp AT hisser DOT org (jamesp AT hisser DOT org)
Date: Wed, 18 Aug 2004 16:53:58 +0100
I don't know anything about your library hardware, but I'm assuming it has a
barcode reader!

You could run robtest from within netbackup, and query the library using "s s"
(show slots). If it says something like barcode = no then the library isn't
giving netbackup any barcode information.

Cheers

James

Quoting "Nguyen, Thomas" <Thomas.Nguyen AT microcell DOT ca>:

> I have a question. I have a netbackup 5.0 , it's running on Win2003 with the
> small robot (Timberwolf) 29 slots & 2 tape drives. I inject manually the
> tape into the robot, when I run inventory, it shows the media tape ID and
> the default media ID (Axxxxx) (ex: I inject 5 tapes in robot, it shows 2
> tapes with the tape ID (N11911, N12128) and the rest are A00051, A00052,
> A00053). Anyone know what is the problem ? how could I resolve it, thanks .
>
>
> Regards
> Tom
>




<Prev in Thread] Current Thread [Next in Thread>